<?xml version="1.0" encoding="UTF-8"?>
<item xmlns="http://omeka.org/schemas/omeka-xml/v5" itemId="21021" public="1" featured="1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://omeka.org/schemas/omeka-xml/v5 http://omeka.org/schemas/omeka-xml/v5/omeka-xml-5-0.xsd" uri="https://hemerotecadigital.uanl.mx/items/show/21021?output=omeka-xml" accessDate="2026-06-24T11:04:04-05:00">
  <fileContainer>
    <file fileId="17427">
      <src>https://hemerotecadigital.uanl.mx/files/original/312/21021/Ingenierias_2020_Ano_23_No_89_Octubre-Diciembre.pdf</src>
      <authentication>26cf7d8b8f33f56af8404a8f334aa0b1</authentication>
      <elementSetContainer>
        <elementSet elementSetId="4">
          <name>PDF Text</name>
          <description/>
          <elementContainer>
            <element elementId="56">
              <name>Text</name>
              <description/>
              <elementTextContainer>
                <elementText elementTextId="586033">
                  <text>�89

		
Contenido
		 Octubre-Diciembre de 2020, Año XXIII, No. 89
3

Editorial: La equidad como uno de los factores
de la logística
José Luis Cantú Mata

6

Remoción del colorante AV7 presente en solución
acuosa mediante carbón activado
Emmanuel Bretón Jiménez, Edwin Javier Melgar Urbina,
Miguel Ángel Hernández Rivera, Margarita Loredo Cancino,
Nancy Elizabeth Dávila Guzmán

14

An agile multi-body additively manufactured
soft actuator for soft manipulators
Jorge Morales, Francisco Ramírez Cruz,
Francisco Eugenio López Guerrero

28

Imágenes fotoacústicas para diagnósticos médicos

Carolyn L. Bayer, Geoffrey P. Luke, Stanislav Y. Emelianov
		

42

O-splines para analizar señales de oscilaciones
de potencia
José Antonio De la O Serna

62

Colaboradores

64

Información para colaboradores

65

Código de ética
Suplemento en línea
“30 años de Nucleoelectricidad en México”
Editores: Max Salvador Hernández, Roberto Carlos Lopez Solis

Ingenierías, Octubre-Diciembre 2020, Año XXIII, No. 89

�

�DIRECTORIO

Ingenierías, Año XXIII N° 89, octubre-

diciembre 2020. Es una publicación
trimestral, editada por la Universidad
Autónoma de Nuevo León, a través de
la Facultad de Ingeniería Mecánica y
Eléctrica. Domicilio de la Publicación:
Facultad de Ingeniería Mecánica y
Eléctrica, Pedro de Alba S/N, Edificio 7, San
Nicolás de los Garza, Nuevo León, México,
C.P. 66450. Teléfono: +52 (81) 83294020
Ext. 5854, Fax +52 81 83320904. Editor
responsable: Dr. Juan Antonio Aguilar
Garib. Reserva de derechos al uso
exclusivo No. 04-2011-101411064600-102,
ISSN: 1405-0676. Número de certificado
de licitud de título y contenido: 15,525,
otorgado por la Comisión Calificadora de
Publicaciones y Revistas Ilustradas de la
Secretaría de Gobernación. Registro de
marca ante el Instituto Mexicano de la
Propiedad Industrial: En trámite. Impresa
por: Desarrollo Litográfico S.A. de C.V., M.
M. del Llano 924 Ote., Centro, Monterrey,
Nuevo León, México, C.P. 64000. Fecha
de terminación de impresión: 15 de
octubre de 2020. Tiraje: 800 ejemplares.
Distribuido por: Universidad Autónoma de
Nuevo León, a través de la Facultad de
Ingeniería Mecánica y Eléctrica, Pedro de
Alba S/N, Edificio 7, San Nicolás de los
Garza, Nuevo León, México, C.P. 66455.
Las opiniones expresadas por los autores
no necesariamente reflejan la postura del
editor de la publicación.
Prohibida su reproducción total o parcial de
los contenidos e imágenes de la publicación
sin previa autorización del Editor.
Impreso en México
Todos los derechos reservados
© Copyright 2020
revistaingenierias@uanl.mx

UNIVERSIDAD AUTÓNOMA DE NUEVO LEÓN
Mtro. Rogelio G. Garza Rivera
Rector

Dr. Santos Guzmán López
Secretario General

Mtra. Emilia Edith Vásquez Farías
Secretario Académico

Dr. Celso José Garza Acuña

Secretario de Extensión y Cultura

Lic. Antonio Ramos Revillas

Director de Editorial Universitaria

FACULTAD DE INGENIERÍA MECÁNICA Y ELÉCTRICA
Dr. Arnulfo Treviño Cubero
Director

Dr. Juan Antonio Aguilar Garib
Editor responsable

M.C. Cyntia Ocañas Galván
Dr. Jesús G. Puente Córdova
Redacción

Gregoria Torres Garay
Tipografía y formación

M.A. José Luis Martínez Mendoza
Diseño

Ing. Cosme D. Cavazos Martínez
Webmaster

René de la Fuente Franco
Impresor

CONSEJO EDITORIAL INTERNACIONAL
Dr. Mauricio Cabrera Ríos, Puerto Rico. UPRM / Dr. Cezar Henrique Gonzalez, Brasil. UFPE, Recife-Pernambuco / Dra. Ruth
Kiminami, Brasil. UFSC, San Pablo / Dr. Juan Jorge Martínez Vega, Francia. Universidad de Toulouse III / Dr. Juan Miguel
Sánchez, USA. UT-Austin / Dr. Zarel Valdez Nava, Francia. UPS-INPT-LAPLACE-CNRS.
CONSEJO EDITORIAL MÉXICO
Dr. Jesús González Hernández, CIDESI / Dr. Benjamín Limón Rodríguez, FIC-UANL / Dr. José Rubén Morones Ibarra,
FCFM-UANL / Dr. Ubaldo Ortiz Méndez, FIME-UANL / Dr. Félix Sánchez De Jesús, ICBI-UAEH / Dr. Ernesto Vázquez
Martínez, FIME-UANL.
COMITÉ TÉCNICO
Dr. Efraín Alcorta García, FIME-UANL / Dr. Rafael Colás Ortiz, FIME-UANL / Dr. Jesús De León Morales, FIME-UANL / Dr.
Virgilio Ángel González González, FIME-UANL / Dr. Carlos Alberto Guerrero Salazar, FIME-UANL / Dra. Oxana Vasilievna
Karissova, FCFM-UANL / Dr. Francisco Eugenio López Guerrero, FIME-UANL / Dr. Martín Edgar Reyes Melo, FIME-UANL /
Dr. Roger Z. Ríos Mercado, FIME-UANL / Dr. Juan Ángel Rodríguez Liñán, FIME-UANL.

�

Ingenierías, Octubre-Diciembre 2020, Año XXIII, No. 89

�Editorial:

La equidad como uno de los
factores de la logística
José Luis Cantú Mata
Universidad Autónoma de Nuevo León,
Facultad de Ingeniería Mecánica y Eléctrica
jose.cantumt@uanl.edu.mx
La administración de la cadena de suministro considera la integración entre
los negocios y las Tecnologías de Información y Comunicaciones (TIC) con
mayor colaboración entre empresas que son parte de una oferta dada, para
generar estrategias diseñadas para tener un mejor posicionamiento, eficiencia
operativa y reducir sus tiempos de respuesta.
Las funciones en la cadena de suministro requieren de procesos
administrativos que vinculan la producción y el comercio con los clientes,
con prácticas habituales de mercadotecnia, compras y logística para satisfacer
al cliente. En este contexto, el área de Logística y Cadena de Suministro
satisface la necesidad de trasladar los bienes, inventario, del productor al
cliente, cumpliendo con diferentes condiciones de tiempo, lugar y costo para
las entregas, acordes a la naturaleza del bien que se suministra. Las actividades
productivas y comerciales se han vuelto de carácter mundial, por lo que no es
extraño que las estrategias surgidas de la logística consideren acciones en el
ámbito internacional.
Un ejemplo reciente de la importancia de la logística se puede apreciar a
través de los retos generados por la emergencia sanitaria del COVID-19 y la
forma en que a pesar de las restricciones de paso de las diferentes fronteras, no
sólo internacionales, sino regionales en ciertos paises, se mantuvo la operación
de uno de los elementos más importantes de la cadena de suministro: el
transporte.
La importancia del transporte de bienes hizo que se le declarara como
una actividad esencial sin más que el seguimiento de ciertos protocolos
para continuarla, pero como se ha podido ver, eso no es suficiente porque la
demanda de las dosis de la vacuna no sigue estándares tradicionales aplicables
a la distribución de otros bienes.
La producción de dosis no cubre la demanda, además de que hay grupos
vulnerables que la requieren con mayor urgencia por lo que es difícil determinar
cómo debe ser distribuida para maximizar el beneficio de la vacunación.
También se debe considerar que se trata de un problema mundial, pero eso
no significa que la distribución óptima en una región, o en un conjunto de
regiones, sea lo mejor para todo el conjunto.
El tiempo es uno de los problemas más graves en una operación logística
de este tipo, pero no hace que otro aspectos, como el costo, desaparezcan del
interés de los organismos empresariales, incluyendo los gobiernos. Para los
paises que no están produciendo las dosis se trata en principio de una compra
en el extranjero, es decir que debe ser importada y luego ponerla en cierto

Ingenierías, Octubre-Diciembre 2020, Año XXIII, No. 89

�

�Editorial: La equidad como uno de los factores de la logítica / José Luis Cantú Mata

lugar a disposición para satisfacer la demanda. Aunque ésta es una operación
de apariencia sencilla en términos de logística, si se toma en cuenta que se
trata de una demanda que incluye aspectos que afectan a la equidad, ya que
no hay producción suficiente para satisfacer la demanda que además no es
uniforme, pues existen grupos que la requieren más que otros. En condiciones
de abundancia los problemas se reducirían al transporte, con el debido manejo
en cuanto a tiempo y seguridad. Pero ya que no es el caso, entonces se formulan
diferentes criterios sobre cómo debería distribuirse.
En la República Mexicana la geografía no es un problema ya que se puede
llegar a prácticamente cualquier población, entonces el criterio podría ser que
los grupos vulnerables vayan primero, pero cómo se define eso, puede ser en
atención a la edad, a las comorbilidades, a las posibilidades de interacción
con otras personas como en las poblaciones grandes, a quienes utilizan el
transporte público, a quienes atienden pacientes con COVID, a quienes
atienden pacientes en cualquier forma: camilleros, choferes de ambulancia,
guardias, administrativos, intendentes, y todas los especialistas médicos en
los hospitales. Éstas son unos cuantos factores para definir y el diseño de la
logística para la distribución bien hecha debe tomarlos en cuenta en busca de
obtener la distribución más equitativa y que maximice su beneficio.
Aunque se recurriera a la estrategia simplista del azar en un sorteo como
una manera para evadir el trabajo serio, es imposible vacunar a todos los que
la dosis alcancen al mismo tiempo, ya que aun disponiendo de ellas para su
aplicación también se deberá organizar otra logística para distribuirlas. Así
que por más que se evite favorecer o desfavorecer a alguien en atención a sus
atributos y necesidades, y por más equitativo que se quiera ser, siempre habrá
alguien que estará en primer lugar para obtener su dosis contra el COVID19.
La supervivencia de los más aptos en cualquier término, ha demostrado a
lo largo de la historia que la equidad no es algo natural, surge del desarrollo
consciente de la sociedad que le ha dado valor, en el fondo a favor de su
preservación sobre la de los individuos de manera que se piensa que los
aspectos discriminatorios o de inequidad no deberían de existir. Se establece
entonces que todos los seres humanos, la población, deben ser tratados por los
demás, no sólo por los gobiernos u organizaciones, sino entre ellos mismos,
equitativamente sin importar las creencias, costumbres o preferencias con
respecto a su raza, género, nivel socioeconómico, entre otros.
Sin embargo, se requiere de una correcta administración y planeación para
que las decisiones que se toman por las estrategias derivadas de la logística
que están orientadas a brindar una satisfacción óptima sean comprendidas,
aceptadas o al menos toleradas por aquellos que no se encontrarán en los
primeros lugares y que se consideran excluidos por una discriminación, según
su percepción, injustificada.
Para estos grupos no importa si la estrategia diseñada es correcta y
se sentirán discrimandos, ya que los criterios que se hace la población en
general están basados en sentimientos y conjeturas populares, si se hiciera
una encuesta, aun una diseñada correctamente que evitara el sesgo y tuviera
una escala de valoración objetiva, las respuestas serían variadas según quienes

�

Ingenierías, Octubre-Diciembre 2020, Año XXIII, No. 89

�Editorial: La equidad como uno de los factores de la logística / José Luis Cantú Mata

las proporcionaran. Es altamente probable que aun aquellos que presuman
de equidad se pondrían al frente. En ocasiones les resulta tan complejo que
terminan aceptando que el azar de un sorteo es la mejor estrategia.
Entonces, si la logística para la distribución es un reto, mucho más reto
será lograrlo con equidad y que sea percibido así. Mientras no se comprenda
claramente la diferencia entre igualdad y equidad, siempre habrá detalles que
por pequeños que parezcan serán interpretados como abuso, falta de equidad,
y en el mejor de los casos, incompetencia de quienes diseñan las estrategias
que buscan favorecer la equidad.
Los problemas logísticos no están limitados a satisfacer demandas
simplemente ubicando los inventarios con seguridad en cierto lugar y tiempo,
poniendo mayor atención al abastecimiento de provisiones sin considerar la
forma en que se abastecen lugares cotidianos cono los pequeños comercios, los
centros comerciales o las tiendas departamentales, de manera que la logística
pasa desapercibida para la sociedad.
Como un ejemplo del logro del diseño de la logística y cadena de suministro
en el cumplimiento de las necesidades de la sociedad ante la emergencia
sanitaria, en que los hábitos de compra se modificaron para evitar su propio
desabasto ocasionando que ésta área tuviera un mayor esfuerzo para el
respectivo abastecimiento. Un ejemplo es que, al principio de la emergencia
sanitaria, la sociedad, quien tuvo acceso a la mercancía, se abasteció de
desinfectante en aerosol y gel antibacterial llegando a la situación del
desabasto en puntos de venta que motivó que se restringiera la venta mientras
se rediseñaba la logística de distribución junto con un cambio radical en la
sociedad que llevó a un mayor control, orden y atención a la existencia de
productos que son necesarios para su supervivencia y artículos de necesidad
básica e higiene.
Las condiciones que se mencionan para la vacunación masiva contra
el COVID-19 no son exclusivas para este proceso, ya que se encuentran
prácticamente en todos los casos en que los aspectos sociales juegan algún
papel que obliga a establecer jerarquías. Lo que si es extensivo y obligatorio
para todos los casos en que se efectúe el diseño de alguna logística, se haga con
método, de manera, sin intentos de improvisación o implementación de ideas
que de momento pueden sonar geniales, pero que no contemplan aspectos
sociales además de los tradicionales de lugar, tiempo y costo.

Ingenierías, Octubre-Diciembre 2020, Año XXIII, No. 89

�

�Remoción del colorante AV7
presente en solución acuosa
mediante carbón activado
Emmanuel Bretón JiménezA, Edwin Javier Melgar UrbinaB,
Miguel Ángel Hernández RiveraA, Margarita Loredo CancinoB,
Nancy Elizabeth Dávila Guzmán*B
Universidad Juárez Autónoma de Tabasco, Cunduacán, México.
Universidad Autónoma de Nuevo León, Facultad de Ciencias Químicas,
Departamento de Ingeniería Química
nancy.davilagz@uanl.edu.mx
A
B

RESUMEN
Se investigó la remoción del colorante ácido violeta 7 mediante carbón
activado en un sistema de adsorción en lote. Se estudiaron los efectos de
parámetros experimentales en la capacidad de adsorción, tales como la masa del
adsorbente y el pH. Las mejores condiciones experimentales para la adsorción de
ácido violeta 7 fueron a pH natural del colorante (pH 6) y 100 mg de adsorbente
al obtener una capacidad de adsorción de 102 mg/g. La cinética de adsorción
fue descrita por el modelo de Pseudo-Segundo orden que está basado en un
mecanismo de quimisorción.
PALABRAS CLAVE
Adsorción; carbón activado; cinética; remoción de colorante.
ABSTRACT
The removal of the acid violet dye 7 by activated carbon was investigated
in a batch adsorption system. The effects of experimental parameters on the
adsorption capacity, such as the mass of the adsorbent and the pH were studied.
The best experimental conditions for the adsorption of acid violet 7 were at the
natural pH of the dye (pH 6) and 100 mg of adsorbent achieving an adsorption
capacity of 102 mg/g. The adsorption kinetics followed the Pseudo-Second
order model which is based on a quimisorption mechanism.
KEYWORDS
Adsorption; activated carbon; kinetics; dye removal.
INTRODUCCIÓN
El rápido crecimiento demográfico y desarrollo económico de la sociedad
humana incrementan las actividades industriales y agrícolas, haciendo un uso
acelerado de agua en todo el mundo. Se prevé que en el año 2050 la población
mundial alcance 9,800 millones de habitantes que podrían llegar a usar hasta un
55% más de agua para satisfacer las necesidades básicas en todo el mundo.1 Los
recursos hídricos han sido explotados de manera descontrolada por industrias
tales como la textil, la papelera, la farmacéutica, la alimentaria y la cosmética,

�

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Remoción del colorante AV7 presente en solución acuosa mediante carbón activado / Emmanuel Bretón Jiménez, et al.

siendo el color la primera evidencia de la contaminación generada.2 Alrededor
de 800,000 toneladas de tintes se producen anualmente en el mundo y el 60-70
% son colorantes. Esto genera un gran impacto ambiental que contaminan las
masas de agua con facilidad, repercutiendo en la salud humana, en las tierras de
cultivo y en la actividad acuícola.3 Los colorantes azoicos son compuestos que
tienen el grupo azo cromóforo (R1–N=N–R2) en sus estructuras moleculares.
Estos grupos funcionales dificultan la biodegradación de los mismos y se
estima que entre el 10 y 15% de estos compuestos se pierde y se incorpora en el
efluente industrial, los cuales deberían ser eliminados antes de ser descargados
a las masas de agua, debido a su alta toxicidad y contaminación provocada
en los ecosistemas.4 El colorante ácido violeta 7 (AV7) es muy importante en
la industria textil y uno de los mayores contribuyentes de la contaminación,5
este colorante está formado por grupos aromáticos complejos y sulfónicos
que lo hacen altamente genotóxico comparado con otros colorantes azoicos.
Los colorantes azoicos afectan a la salud humana, y al medio ambiente. En los
últimos años, algunos científicos han tratado de resolver esta problemática.
Entre los diversos métodos de eliminación comúnmente utilizados destacan
la adsorción, foto-degradación y decoloración microbiológica, entre otros.6
En general, la adsorción de colorantes de la industria textil sobre materiales
sólidos como el carbón activado (CA) resulta eficiente gracias a la relativa
simplicidad del sistema y a las propiedades del carbón activado, como elevada
área superficial, estabilidad química y alta capacidad de adsorción.7 El CA ha
sido utilizado en la purificación del aire, remoción de colorantes y contaminantes
farmacéuticos, entre otros.8 Por lo tanto, en esta investigación se evaluó la
capacidad del CA para la remoción del contaminante AV7, a través del estudio
de equilibrio y cinético del proceso de adsorción.
MATERIALES Y MÉTODOS
Reactivos y materiales
El carbón activado utilizado fue de origen mineral, con tamaño de partícula
de 500-700 µm (Clarimex). El ácido violeta 7 fue provisto por Sigma-Aldrich
en forma de polvo, tiene un peso molecular de 566.47 g/mol y su fórmula
química es C20H16N4Na2O9S2.
Preparación del adsorbato
Una solución patrón de ácido violeta 7 de 50 mg/L se preparó añadiendo
0.05 g de ácido violeta 7 sólido en un matraz volumétrico de 0.025 L con agua
desionizada, agitándose hasta obtener una solución homogénea color violeta.
Análisis de concentración del adsorbato.
La concentración del adsorbato fue cuantificada en un espectrofotómetro
(Genesis 10S UV/Vis) utilizando una curva de calibración. Los estándares del
AV7 fueron preparados a partir de la solución patrón para obtener concentraciones
de 1 mg/L, 2 mg/L, 5 mg/L, 10 mg/L y 25 mg/L Posteriormente, se registró la
absorbancia de cada estándar a una longitud de onda de 510 nm.

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�

�Remoción del colorante AV7 presente en solución acuosa mediante carbón activado / Emmanuel Bretón Jiménez, et al.

Experimentos de cinética de adsorción
La cinética de adsorción de AV7 sobre CA fue obtenida añadiendo una masa
definida de CA a un matraz Erlenmeyer de capacidad nominal de 250 mL, la cual
fue puesta en contacto con 100 mL de AV7 a una concentración inicial de 50 mg/L.
La mezcla se mantuvo en agitación constante a 200 rpm y a temperatura ambiente
(25 ºC) durante un tiempo de contacto de 6 h (para asegurar alcanzar el equilibrio).
Se tomaron alícuotas de 1 mL de la solución a diferentes tiempos (5, 10, 20,
30, 60, 90, 120, 150, 180, 240, y 360 min) para su posterior análisis mediante
espectrofotometría UV-Vis. La cantidad de colorante adsorbido en cualquier
tiempo, q (mg/g), se calculó por medio del siguiente balance de masa:
(1)
Donde Co y C son las concentraciones iniciales y a cualquier tiempo de AV7
(mg/L), respectivamente; V es el volumen de la solución (L) y m es la masa del
adsorbente (g).
El porcentaje de remoción del adsorbente en el equilibrio fue calculado
mediante la siguiente (ecuación 2):
(2)
Donde Ce es la concentración de AV7 en el equilibrio (mg/L).
Efecto de la masa del adsorbente
La cantidad empleada del adsorbente CA es un parámetro muy importante
en el estudio de adsorción ya que determina la capacidad del adsorbente para
tratar una solución coloreada de una concentración inicial dada. Para el estudio
del efecto de la masa del adsorbente se realizaron experimentos con tres niveles
(100, 200 y 300 mg) al pH natural del colorante; a una concentración inicial de
50 mg/L de AV7 (tabla I). Es importante mencionar que el pH no fue controlado
durante los experimentos de adsorción.
Efecto del pH sobre la capacidad de adsorción
El pH de la solución es un parámetro muy importante en el proceso de adsorción
ya que puede afectar la interacción de los grupos funcionales superficiales del
adsorbato y el adsorbente, además, las propiedades del CA y de los colorantes
podrán indicar si la adsorción es favorable en disoluciones ácidas o básicas.9 El
efecto del pH sobre la capacidad de adsorción se evaluó en tres niveles de pH
(3, 5 y 7), a una concentración inicial de 50 mg/L de AV7 (tabla II). El pH fue
controlado durante el proceso de adsorción, mediante la adición de alícuotas de
HNO3 y NaOH al 0.1 N según el caso.
Tabla I. Condiciones experimentales para evaluar el efecto de la masa de CA sobre la
capacidad de adsorción AV7.

�

Experimentos

CA-100

CA-200

CA-300

pH inicial

6

6

6

Masa CA (mg)

100

200

300

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Remoción del colorante AV7 presente en solución acuosa mediante carbón activado / Emmanuel Bretón Jiménez, et al.

Modelación matemática de la cinética de adsorción
Los modelos de Pseudo-Primer orden y Pseudo-Segundo orden fueron
empleados para la modelación matemática de las cinéticas de adsorción de AV7
en carbón activado. El modelo de Pseudo-Primer orden supone que la velocidad
de adsorción con respecto al tiempo es proporcional a la diferencia entre la
capacidad de adsorción en el equilibrio (qe) y la cantidad adsorbida en un tiempo
determinado (qt), tal como se muestra en la (ecuación 3).
(3)
Al integrar la Ec. 3 en q(0)=0 y q(t)=qt se obtiene la Ec. 4:
(4)
Por otro lado, el modelo de Pseudo-Segundo orden supone que el paso
limitante de la velocidad corresponde a la etapa de quimisorción, tal como se
muestra en la Ec. 5:
(5)
Integrando en q(0)=0 y q(t)=qt se obtiene la Ec. 6:
Tabla II. Condiciones experimentales para evaluar el efecto del pH sobre la capacidad
de adsorción de AV7.
Experimentos

CA-3

CA-5

CA-7

pH

3

5

7

Masa CA (mg)

100

100

100

(6)
Los parámetros de los modelos cinéticos fueron obtenidos mediante la
minimización de la suma de los errores al cuadrado (Ec. 7) utilizando la
herramienta Solver® de Microsoft Excel. Por otra parte, el coeficiente de
determinación (R2) fue calculado con la (Ec. 8).
(7)

(8)
Donde
son la capacidad de adsorción calculada con el
modelo cinético, la capacidad de adsorción experimental, y el promedio de la
capacidad de adsorción experimental, respectivamente, en mg/g, n es el número
de datos experimentales y k es el número de los parámetros del modelo.
RESULTADOS Y DISCUSION
Efecto de la masa sobre la capacidad de adsorción
Se evaluó la capacidad de adsorción de AV7 en CA a diferentes masas de
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89	�

�Remoción del colorante AV7 presente en solución acuosa mediante carbón activado / Emmanuel Bretón Jiménez, et al.

adsorbente (figura 1). Los resultados muestran que conforme la cantidad de masa
aumenta de 100 a 300 mg de CA, la capacidad de adsorción disminuye de 102 a
33.8 mg/g. Por otra parte, con el incremento de la masa de CA se observó un menor
tiempo para alcanzar el equilibrio al pasar de 240 a 180 min para el experimento
con CA-100 y CA-300, respectivamente. Estos resultados pueden ser atribuidos a
que conforme se incrementa la cantidad de adsorbente se aumenta la cantidad de
sitios de adsorción con lo que se favorece la velocidad de adsorción de AV7.

Fig. 1. Efecto de la masa sobre la cinética de adsorción. Condiciones: pH (6) natural
del colorante, 25ºC, Co=50 mg/L.

Por otra parte, el porcentaje de remoción de AV7 aumentó de 79.3% a 91.6%
para un incremento de la masa de adsorbente de 100 a 300 mg (figura 2). En
conclusión, los sitios de adsorción disponibles para la remoción de AV7 dependen
de la cantidad de adsorbente añadida a la solución.10

Fig. 2. Efecto de la dosis de masa de adsorbente en el porcentaje de remoción.

10

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Remoción del colorante AV7 presente en solución acuosa mediante carbón activado / Emmanuel Bretón Jiménez, et al.

Efecto del pH sobre la capacidad de adsorción
En la figura 3, muestra como disminuye la capacidad de adsorción del CA
cuando se aumenta el pH de la solución. A pH 5 se obtuvo la mayor capacidad
de adsorción (86.6 mg/g) mientras que a pH 7 la capacidad de adsorción fue
61.4 mg/g. A pH ácidos (3 a 5) la concentración de iones hidrógeno (H+)
aumenta, cargándose positivamente la superficie del CA, situación que facilita
las atracciones electrostáticas con las moléculas del colorante AV7 de condición
aniónica. Se ha demostrado que a un pH ácido es posible que se formen centros
electrofílicos en el CA que pueden generar atracciones de naturaleza electrostática
con adsorbatos aniónicos.11

Fig. 3. Efecto del pH sobre la cinética de adsorción de AV7. Condiciones: pH (3,5,7)
controlado durante todo el experimento y pH (6) sin control, 25°C, Co de 50 mg/L y
100 mg de CA.

Modelación matemática de la cinética de adsorción
Los datos de cinética de adsorción fueron ajustados a los modelos de Pseudoprimer orden y Pseudo-segundo orden (figura 4). Se encontró que el modelo de
Pseudo-segundo orden es el modelo que mejor predice la cinética de adsorción
de AV7 en CA, considerando la magnitud del error obtenido. De acuerdo al
modelo de Pseudo-segundo orden, el proceso de adsorción está controlado por un
mecanismo de quimisorción. Los parámetros de los modelos cinéticos obtenidos
se encuentran reportados en la tabla III.
Tabla III. Parámetros cinéticos de los modelos de pseudo-primer orden y pseudo-segundo
orden en la adsorción de AV7 sobre CA.
Pseudo-Primer orden
K1 (min )

0.072

-1

R

0.891

2

SEC

1656.12
Pseudo-Segundo orden

K2 (g mg min )

0.001

R2

0.958

SEC

434.53

-1

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

-1

11

�Remoción del colorante AV7 presente en solución acuosa mediante carbón activado / Emmanuel Bretón Jiménez, et al.

Fig. 4. Comparación de los modelos cinéticos de adsorción de pseudo-primer orden y
pseudo-segundo orden para la remoción de AV7 con CA a 25ºC.

CONCLUSIONES
Se investigó el potencial del CA comercial como material adsorbente en la
remoción de AV7 en soluciones acuosas. Se estudiaron los efectos de parámetros
tales como masa del adsorbente, pH natural del colorante (6) y pH (3, 5 y 7). La
mayor capacidad de adsorción fue obtenida en el experimento CA-100 con una
masa de 100 mg de CA con un valor de 102 mg/g a pH natural del colorante (6).
La cinética de adsorción fue descrita por el modelo de Pseudo-segundo orden,
el cual está basado en un mecanismo de quimisorción. Por lo tanto, este estudio
demuestra que el adsorbente CA de origen comercial puede ser una alternativa
eficiente para la remoción de colorantes azoicos en tratamientos terciarios de
aguas residuales, además, la capacidad de adsorción aumentó al utilizar un pH
natural (6), al no requerir la adición de más reactivos a la solución se puede
reducir el costo de operación.
REFERENCIAS
1. Chen, L., Huang, K., Zhou, J., Duan, H. F., Zhang, J., Wang, D., &amp; Qiu, H.
(2020). Multiple-risk assessment of water supply, hydropower and environment
nexus in the water resources system. Journal of Cleaner Production, 268,
122057. https://doi.org/10.1016/j.jclepro.2020.122057.
2. Hincapié Mejía, G., Cardona Cuervo, S., &amp; Ríos, L. A. (2018). Absorption
thermodynamic study of azoic dye with by means of a lignocellulosic waste
in aqueous medium. Ingeniería y Desarrollo, 36(1), 97–118. https://doi.
org/10.14482/inde.36.1.10941.
3. Ben Mansour, H., Corroler, D., Barillier, D., Ghedira, K., Chekir, L., &amp;
Mosrati, R. (2007). Evaluation of genotoxicity and pro-oxidant effect of the
azo dyes: Acids yellow 17, violet 7 and orange 52, and of their degradation
products by Pseudomonas putida mt-2. Food and Chemical Toxicology, 45(9),
1670–1677. https://doi.org/10.1016/j.fct.2007.02.033.

12

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Remoción del colorante AV7 presente en solución acuosa mediante carbón activado / Emmanuel Bretón Jiménez, et al.

4. Moutaouakkil, A., Zeroual, Y., Dzayri, F. Z., Talbi, M., Lee, K., &amp; Blaghen,
M. (2003). Purification and partial characterization of azoreductase from
Enterobacter agglomerans. Archives of Biochemistry and Biophysics, 413(1),
139–146. https://doi.org/10.1016/S0003-9861(03)00096-1.
5. González-Casamachin, D. A., Rivera De la Rosa, J., Lucio-Ortiz, C. J., De
Haro De Rio, D. A., Martínez-Vargas, D. X., Flores-Escamilla, G. A., Dávila
Guzman, N. E., Ovando-Medina, V. M., &amp; Moctezuma-Velazquez, E. (2019).
Visible-light photocatalytic degradation of acid violet 7 dye in a continuous
annular reactor using ZnO/PPy photocatalyst: Synthesis, characterization,
mass transfer effect evaluation and kinetic analysis. Chemical Engineering
Journal, 373(March), 325–337. https://doi.org/10.1016/j.cej.2019.05.032.
6. Forgacs, E., Cserháti, T., &amp; Oros, G. (2004). Removal of synthetic dyes from
wastewaters: A review. Environment International, 30(7), 953–971. https://doi.
org/10.1016/j.envint.2004.02.001.
7. Rafatullah, M., Sulaiman, O., Hashim, R., &amp; Ahmad, A. (2010). Adsorption
of methylene blue on low-cost adsorbents: A review. Journal of Hazardous
Materials, 177(1–3), 70–80. https://doi.org/10.1016/j.jhazmat.2009.12.047.
8. Oladejo, J., Shi, K., Chen, Y., Luo, X., Gang, Y., &amp; Wu, T. (2020). Closing
the active carbon cycle: Regeneration of spent activated carbon from a
wastewater treatment facility for resource optimization. Chemical Engineering
and Processing - Process Intensification, 150(November 2019), 107878.
https://doi.org/10.1016/j.cep.2020.107878.
9. Vargas, A. M. M., Cazetta, A. L., Martins, A. C., Moraes, J. C. G., Garcia, E. E.,
Gauze, G. F., Costa, W. F., &amp; Almeida, V. C. (2012). Kinetic and equilibrium
studies: Adsorption of food dyes Acid Yellow 6, Acid Yellow 23, and Acid
Red 18 on activated carbon from flamboyant pods. Chemical Engineering
Journal, 181–182, 243–250. https://doi.org/10.1016/j.cej.2011.11.073.
10. Bhatti, H. N., Mumtaz, B., Hanif, M. A., &amp; Nadeem, R. (2007). Removal of
Zn(II) ions from aqueous solution using Moringa oleifera Lam. (horseradish
tree) biomass. Process Biochemistry, 42(4), 547–553. https://doi.org/10.1016/
j.procbio.2006.10.009.
11. Castelar Ortega, G. C., Viloria C, C. A., Morrinson B, C. A., Angulo M, E. R.,
&amp; Zambrano A, A. M. (2017). Evaluación de un carbón activado comercial
en la remoción del colorante DB2. Revista Colombiana de Ciencia Animal
- RECIA, 9(2), 164. https://doi.org/10.24188/recia.v9.n2.2017.512.

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

13

�An agile multi-body additively
manufactured soft actuator
for soft manipulators
Jorge Moralesa, Francisco Ramírez Cruzb,
Francisco Eugenio López Guerrerob

Chair of Production Automation and Assembly, University of Siegen,
Paul-Bonatz-Str. 9-11, 57076 Siegen, Germany
b
Universidad Autónoma de Nuevo León, Facultad de Ingeniería Mecánica y
Eléctrica, Departamento de Mecatrónica
a

RESUMEN
Con la introducción de robots colaborativos en entornos de producción, el
daño a los trabajadores por el uso de robots tradicionales con enlaces rígidos
es inherente. Se ha propuesto una nueva generación de robots hechos de
materiales blandos flexibles que reduce el peligro de colisión mediante acciones
de autodeformación como una solución prometedora para los entornos de
colaboración humano-robot. Recientemente, con el desarrollo de la fabricación
aditiva de materiales blandos elásticos, surgen nuevas oportunidades de diseño
para estos llamados robots blandos. Sin embargo, aún no se logra la robustez
que se requiere para los entornos de producción. Este documento presenta un
enfoque de diseño de un actuador neumático blando de tres ejes fabricado de
forma totalmente aditiva. Para su uso en sistemas de manipuladores robóticos
blandos flexibles, se presentan pautas de diseño, un proceso de impresión 3D
directo con materiales elásticos y un sistema de control de regulación de presión
semiautomatizado PLC de bajo nivel. Para validar el diseño propuesto, el
actuador se fabrica y prueba para la fuerza de contacto máxima, la reacción de
movimiento de flexión y su respuesta de señal.
PALABRAS CLAVE
Materiales blandos, fabricación aditiva, robots blandos, sistema de control.
ABSTRACT
With the introduction of collaborative robots in production environments, the
harm to workers by using traditional robots with rigid links is inherent. A new
generation of robots made from flexible soft materials that decreases collision
danger by self-deforming actions has been proposed as a promising solution for
the human-robot collaboration environments. Recently, by the development of
additive manufacture of elastic soft materials, new design opportunities arise for
these so-called soft robots. However, robustness that is required for production
environments is still not achieved. This paper presents a design approach of a
fully additively manufactured three-axis soft pneumatic actuator. For its use in
flexible soft robotic manipulator systems, design guidelines, a direct 3D printing
process with elastic materials and a low-level PLC semi-automated pressure

14

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

regulation control system are presented. To validate the proposed design, the
actuator is manufactured and tested for maximum contact force, bending motion
reaction and its signal response.
KEYWORDS
Soft materials, additive manufacture, soft robots, control system.
INTRODUCCIÓN
In human-robot collaboration environments, where the proximity between
human and robot potentially rises a harmful and non-safe working environment.
In the case of robot-assisted assembly processes the idea of having a robot
operating beside a worker difficult. With the introduction of cobots in the last
years, this human-robot collaboration is still not well accepted for workers that
claim not feeling safe working together with a robot in the vicinity. The use of
soft material robots that can operate in the vicinity without being a threat for the
user provide a promising perspective of future shop floor collaboration. Since1
pneumatic-driven flexible actuators have been started to be described and their
application in certain robotic mechanism.
With the increased and fast emerging development of additive manufacturing
technologies, it has been proved that, design and fabrication of complex
geometrical structures is possible nowadays.2 A more universal way of application
is achieved with soft robots because these soft materials, often elastomers, allow
them to flexibly adapt to their working environment in terms of conventionally
inaccessible work environments (e.g. under sea).3 Even more, soft robotic grippers
can cling to various shapes and, thus, handle a broader range of applications, as in4
were a soft manipulator has been introduced as surgical manipulator. Furthermore,
inherently soft, and flexible materials, such as silicon-based polymers, are now
available for additive manufacturing.
In industrial and production environments, rigid robots are very well stablished
due the robustness and strength capabilities that even small cobots models, can
handle several kilograms of payload. In practical robotic applications, the use of
end attached tools play a significant role in the mass and speed along a desired
motion direction.5 Payload is usually a requirement for production processes that
cannot be neglected or replaced with the use of soft rubber-like materials. Adding
mass to these so called, soft actuators raises the gravitational load, which for in a
multi-body soft manipulator configuration, results in larger joint tor-ques and have
a big influence in the required energy in order to maintain its deformed position.
For pneumatically operated actuators and as investigated in,6,7,8,9,10 generated
blocked force is still very low for a pneumatically actuated net-work, usually
for a single PneuNet, values are in the 3 N surroundings. For AM soft materials,
forces are usually lower than what casted materials can offer. Recent studies as
in11 analyzes lifting and twisting forces for handling different objects.
However, the lack of material testing standards for AM soft polymers
and material models rises the challenges of how-to bring AM soft robots to a
performance level to functionally compete with classical rigid robots. Recent
works as in,12 offer a perspective on mechanical properties and characteristics
for different types of elastomers used in soft robotics applications. Nevertheless,
durability of available materials represents yet an unanswered question.
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

15

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

Fig. 1. Conceptual design of a fully additively manufactured soft robotic arm
manipulator.

In this work, a three-axis additively manufactured soft silicon-based body segment
for a soft manipulator is presented. In order to overcome classic fabrication
challenges as presented in,9 a uni-body fully additively manufactured segment
of a multi-body smart manipulator is investigated. Besides the design challenges
inherent to AM, the maximum displacement that the element can achieve, as
the maximum force and momentum are measured and analyzed in this work.
The aim of this paper is to design and characterize a single fully 3D printed soft
silicon actuator.
Starting from a conceptual sketch for a multi-body flexible manipulator as
seen in figure 1, this work presents a new design approach of a unibody element
that can be easily manufactured and assembled to form a more complex soft
robot arm manipulator. Together with an automated PID low level control and
a semi-automated PLC system, the actuator is tested for different pressure set
points and the resultant force for each case is also measured.
Based on previous works, 13,14 we have discussed the advantages and
disadvantages of the additive manufacture of soft actuators using silicon-based
materials, that together with a new design perspective, targeted for a fully AM
fabrication we investigate how fabrication challenges and controllability issues
can be handled for the introduction of such actuators as reliable products in
production processes. Due to the problems associated with fabrication and
assembly of soft material actuators and robots, we focus on the development of
a single fully 3D printed actuator as one element of a manipulator body. Drawing
from previous experiences and expertise in additive manufacture of soft materials
as in,13,14 and in comparison with typical manufactured actuators where shapes
and features, due to the complexity of casting, is limited, as presented in8 see
(figure 2a), we present an innovative three axis design for a unibody soft actuator
(see figure 2b).

16

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

Fig. 2. a) Typical design [7] in conventionally molded fabrication setup (upper parts)
and b) chances for AM fabricated actuators (lower parts).

In this paper, we intend to demonstrate the possibility to fully 3D print a soft
actuator, that can be later used to build a fully 3D printed soft robotic manipulator.
An easy-to-build approach and a reliable air pressure supply signal is the key to
reduce the fabrication,15 and control,16,17 complexity that until now, soft robots
present.18
Traditionally soft robots manufactured by casting, which is usually a long
process that, due to fabrication of molds, and the process itself of pouring
and curing tend to be time consuming. Molds are already 3D printed,19,20 in
order to achieve the com-plex geometry forms, that are required for such soft
robots. However, the stepwise nature of this classical fabrication method,21,8 the
material waste and post processing effort that compared in an almost not need
of post processing or material waste, as it 3D printing, makes it a unique product
manufacture solution at low volumes in a cost-effective way.22 Therefore, additive
manufacture has the potential to scale better.
Furthermore, 3D printing allows integrating geometrical features in parts to
improve functionality. In contrast to classical methods, the main disadvantage of
AM yet is the lack of mechanical performance, as known from the conventional
silicone-based polymer compounds. As described in,23 the type of material has
a direct influence on the shape, dimensions, durability, applications and costs
of printed parts. Despite problems with durable integrity, the easy manufacture
of soft material components for the application in production engineering is
advancing. Our study, therefore, evaluates the reliability of the materials used,
its motion response and its operational force in a robotic force sensing test as
in,24 using automated PID regulated air pressure signals.
OBJECTIVES
This work is focused on if and how a direct AM process can be applied for the
fabrication of soft material bio inspired manipulators. We present an easy-to-build
uni-body design approach for a modular, multi-body manipulator. In this context,
AM enables substitution of several components by integration of their respective
functionality. The differential design and construction as well as elaborate
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

17

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

assembly steps of conventional manufacturing processes is hence avoided. We
investigate how a design for AM affects the challenges related to this fabrication
process and if such actuators can perform in production process environments.
A prototype of a module is built and tested for maximum forces generated and
the reaction of automated control signals. A two-element manipulator prototype
is investigated for its motion response.
MATERIALS AND METHODS
The material “agilus30” white from the manufacturer Stratasys was used in this
work for fabrication of the soft robotic unit. The mechanical material parameters,
as given by Stratasys in,20 and are summarized in table I.
Table I. OEM mechanical parameters.
Parameter

Unit

white

black

Tensile strength

[MPa]

2.1 – 2.6

2.4 – 3.1

Failure elongation

[%]

180 – 230

220 – 270

Density

[g/cm3]

1.14 – 1.15

1.14 – 1.15

Shore A hardness

-

30 – 40

30 – 35

Design for additive manufacture
Machine developers have been introducing in recent years soft, elastic
materials. Such materials arise the challenges even more on how to design
functional and reliable components. For designers, who lack design guidelines,
standards and manufacture norms are already challenges,25 these new materials
came with a set of valuable mechanical properties, as is high elasticity and
deformation levels. As has been seen in,26,13 there are some design requirements
that for this work are considering:
• Full removal of internal support materials
• Unibody design
• Easy and fast fabrication
• Lightweight and minimum material usage
• Easy to assembly
• Expected maximum force F &gt;= 10N
Figure 3 displays the final design of the actuator. Based on our own previous
experience,11 for design and additively manufacture soft actuator form the PneuNet
type a three-chambers unibody design is proposed. Each of the internal chambers
as is shown in figure 3d is interconnected trough a main channel where, when
air fulfill the volume, these tend to expand the chamber with a uniaxial total
directional bending motion.
Fabrication process
Due to the advantages of direct 3D printing technologies, as is the development
of new materials, a single two-steps fabrication process was required. Fabrication
process presented on this work was made using a Stratasys PolyJet Connex

18

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

Fig. 3. a) front view of the final actuator design, b) isometric view, c) cut-view of the
internal air inlets as is finally assembled, d) cut-view internal chamber and channel.

3 series. Removal of support material is conducted in our laboratory using a
potassium hydroxide solution as a solver. Fully removal of support material is
still an issue for the deepest internal pneumatic chambers, however, machine
manufacturers now offering chemical solutions to react and remove such supports
improves significantly the cleaning process. In figure 4, the resulted component
is shown.

Fig. 4. Final product overview. Support materials are already being removed for a total
mass m = 190gr and a total length l = 108mm.

Bending forces
The three-axis AM actuator’s design essentially resembles a tube with three
PneuNets, longitudinally attached under an angle 120 degree towards each other.
In order to predict the component’s elastic behavior, the structural stiffness needs
to be considered. Figure 5 shows the schematic cut view with relevant dimensions
of the soft robotic unit.
Mechanically, the component’s PneuNets are integrated in a way, so that
they do not significantly contribute to stiffness, which, overall, is determined by
the centric tube feature. In order to derive the force, which is generated by the
actuator, elastic bending stiffness of a tube needs to be considered.
(1)

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

19

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

Fig. 5. Mechanical representation of the soft robotic component, explaining coordinates
and labels.

under consideration of the inertia I
(2)
As a first approach, the elastic modulus E can be expressed as tensile strength
over fracture elongation, knowing, that the used material would reveal significant
non-linearity in its elastic characteristic (visco- or hyperelastic). For PneuNets,
Polygerinos et al.3 have suggested the following expression to calculate force
response ΔF resulting from inner pneumatic excitation ΔPi
(3)
with the width- (c) justified lever LW = l/c. The variable Ma (bending moment)
takes the PneuNets pressurized dimensions into account and allows to carefully
study the sensitivity towards changes in design.
(4)
Because of the triangular chamber shape of the presented PneuNets, as seen
in figure 5, height b is justified by two thirds and d is calculated as average gap
over height.
Experimental setup
The behavior of the soft robotic actuator is studied under its inflation by air
pressure. For the evaluation of force, it initially rests hanging from a flange mount
with its tip, opposite to the excited PneuNet pointing against a force sensor. A
DELTA F/T transducer force-momentum sensor, with a resolution of CTL = 1/8
and NET F/T = 1/16 on Fz is employed to evaluate the force, that is generated
by the actuator.

20

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

Fig. 6. FESTO Motion Terminal, with an 8-valve configuration for up to 16 parallel
pneumatic outputs.

In order to supply and control pressure that for soft actuators a FESTO Motion
Terminal (VTEM),27 is used (see figure 6). Implementation of a fully automated
PLC environment allowed us to concentrate in our own control system signal
development without the problematic that piezo actuated valves and magnetic
flow valves present.
Our experimental setup can be seen in figure 7. The force sensor attached
to a UR5 lightweight robot helps to easily modify the contact distance of the
unpressurized and pressurized states of the actuator as in.24 For this work, only
displacement and motion in one plane where captured, in future works, a threedimensional motion trajectory capture is planned.

Fig. 7. Front view of the experimental setup. The actuator rest in an unpressurized
state position.

The importance of this experimental setup is, to acquire enough information
about if an additively manufactured actuator can provide a load force enough to
be implemented in a multi-body soft robot configuration. Most commonly, soft
actuators are characterized by terms of their deformation against pressurization,
but as presented by,19 only a few newtons of force are obtained (1 – 4N). For this
work, a minimum expected load of 10N is expected in order to carry on further
experiments on an increased payload.
Results and discussions
The physical experiments of pressurizing the soft robotic actuator with a ramp
signal, deliver its static response.
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

21

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

Bending force and momentum
The force signal of the actuator was evaluated with a step width of 100 mbar.
In figure 8a, a force over pressure plot is presented with inflation until rupture
during the last experiment.
The actuators force over pressure response shows a linear increasing trend up
to 1 bar internal pressure, as predicted by the model developed in eqns. 3 and 4.
Deviations from the prediction are suspected to result the fact that the piezo valves
used for this work does not react up to a minimum of 100mbar pressure, that
explain the offset in the origin of the diagram. It was also found, that the PneuNets
mechanical model shows high sensitivity against dimensioning the height
parameter b. The “model 1” represent the ideal bending force mathematically
calculated in comparison with the model from.19 Two tests were performed to
corroborate the measured force. Results show in “Test1” and “Test2”, see figure
8, how force values remain almost identical trough the test. The “Model” line
represents an adjusted linear model of the expected ideal. In our case, during the
first 130 mbar of pressurization in which the pressure controller does not react
yet and due to the distance of 1mm in between the force sensor attached to the
robot, force cannot be measured in the interval from 0 to 130 mbar. Pressure levels
going over 1 bar were starting to produce some damage on the outside walls of the
actuator, meaning, that internal cracks were already propagated trough the walls
of the chamber. At the point of 1.1 bar, fissures caused by extreme elongation on
the zones where the networks are connected showed up as seen in figure 8b.

Fig. 8. a) Comparison to model at 1100 mbar pressurized state (rupture point), b) optical
evaluation of the actuator begore rupture at a force state of 1100 mbar.

22

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

Because the presented new triangular actuator design strongly diverges from
the plain rod design presented in,19,28 it is still unclear which dimensioning of
height to use for optimized results. The angled chambers need to be paired respect
to, because this PneuNet design reasonably will generate most force at the base
of the network. The height factorized by 2/3 is thus chosen for a) its geometrical
explanation with respect to the triangular PneuNet shape and b) the observed
match of model’s incline to the plots of the experiments. It can be noticed, that
a quasi-linear relationship occurs in between pressure and force, with nearly 1N
increment each 100 mbar (see figure 9). Despite this, a supply pressure over 1
bar caused damages up to rupture on the actuator, this said, there still no chance
to provide a reliable safety factor. Design parameters such as already mentioned
height need to be optimized for a better expected reliabiltiy.

Fig. 9. 1 mm stepwise variation of computed chamber height illustrates the sensitivity
of the mechanic model for statically pressurized PneuNets.

Motion response
Control of soft robots and actuators is mostly difficult due lack of good models
that describe or represent their behavior. The complexity of such systems, has
been hardly studied in recent works, such as in29 and.30 For this case, FESTO
piezo pilot-controlled valves27 combined with model based proportional pressure
regulation functions (i.e. ramps) are coupled with our soft actuator. The system is
capable to supply up to 16 parallel air pressure continuous and cyclic signals (see
figure 6) with a range of discrepancy in between the 25 mbar on each output. The
linearity error for our system varies in between the 60-100 mbar and a maximum
hysteresis of 25 mbar.
In contrast, for small air volumes, the PID controller has a response sensitivity
of 80 mbar. Therefore, the controller is activated not before a setpoint of 100
mbar, as it can be seen in figure 10, otherwise, the port is exhausted.
Pressure sensors are directly integrated on the valves, with the model-based
proportional pressure regulation, any pressure drops caused by a change in the
pressure in the tubing or chambers, is calculated and compensated. Due to lack of
material models and well-known problems on controlling such complex systems,
this work is focused on the pure pressure regulation and control. It can be seen
in figure 10 that a pressure stabilization time varies within the set point value.
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

23

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

Fig. 10. ramp signal up to 600 mbar. The signal was given with a 5 s increment time,
20 s pressurized state and 5 s depressurization time.

For higher pressure target points, the controller tends to regulate the pressure faster
than for small volumes (&lt;130mbar). In figure 10, for a target point of 600 mbar
it took approximately 8 s for the controller to equilibrate the signal. In contrast
to our comparison model taken from,19 and due the limitations of piezo valves,
the possibility to control such small air volumes is difficult.
Two-Element motion test
One of the challenges of multi-body soft manipulators is to couple each
element. We design a quick-change coupling system to increase the assembly
and testing agility of our manipulator system. This work presents only a
bending motion overview of two independent actuators interconnected to
create a two-element fully additively manufactured soft robot manipulator.
As presented in figure 11, it can be seen how the bending behaviour of one
independent element is affected when adding more elements to the manipulator.

Fig. 11. Deformation coordinates in mm for one plane at a 400 mbar pressure input. (a)
one actuator, no pressure input; (b) one actuator, pressurized state; (c) two actuator
and quick exchange coupling system, pressurized state.

24

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

This change in motion, will seriously affect the soft robotic manipulator
dynamic characteristics. Such motion influences could translate into higher air
pressurization levels in a multi-body configuration to achieve similar bending
angles of independent actuators. Such input parameters need to be considered
during the design phase in order to avoid a component failure due to inflation
levels. In future works, these changes will be further investigated.
Conclusions and future work
In this work we have presented a design approach for AM that show how
a typical stepwise casting process for silicon materials can be avoided. Which
lead to an easy-to manufacture product. The additive manufactured actuator
was designed in consideration to being additively manufactured and actuated
with a set of three internal PneuNet type chambers and channels. The results
showed that is possible to get a significant amount of tip force (11N) in a quasicontrolled environment. Considering that the actuator force can be increased
while pressurizing more than one chamber, as not performed in this work yet,
we will analyze how the simultaneous multi-axis behaves in the space and how
the use of sequential signal inputs can achieve predefined primitive motions in
order to implement basic pick &amp; place operations in zones difficult to reach (i.e.,
automotive cockpit cabling).
It was also demonstrated that to use this actuator altogether as a fully AM
manipulator, the load force needs to be still incremented. A set of design
parameters as the PneuNet height and length will be further investigated. Also,
the use of a more robust actuator as the first element of our manipulator can help
to increase the overall stiffness and increase maximum payload. The actuator
has a mass of only 190 gr, while in a full multi-body configuration is planned to
weight around 800 gr, while typically robotic arms e.g., a Universal Robot UR3
has a mass of 11.2 kg. This can imply that the harm that classical robots represent
for workers in production environments can considerably be reduced using soft
materials. Furthermore, more complex control methods will be investigated for
an independent signal response of each chamber through the whole manipulator
and a soft AM gripper. Dynamic behaviour for a multi-element soft manipulator
needs to be further investigated and evaluated in a 3D spatial configuration.
REFERENCES
1. K. Suzumori, “Development of Flexible Microactuator and Its Applications to
Robotic M.” .
2. C. Schumacher, B. Bickel, J. Rys, S. Marschner, C. Daraio, and M. Gross,
“Microstructures to control elasticity in 3D printing,” ACM Trans. Graph., vol. 34,
no. 4, pp. 136:1-136:13, 2015, doi: 10.1145/2766926.
3. B. T. Phillips et al., “A Dexterous, Glove-Based Teleoperable Low-Power Soft
Robotic Arm for Delicate Deep-Sea Biological Exploration,” Sci. Rep., vol. 8, no.
1, pp. 1–9, 2018, doi: 10.1038/s41598-018-33138-y.
4. I. De Falco, M. Cianchetti, and A. Menciassi, “Stiff-flop surgical manipulator: design
and preliminary motion evalutaion,” 4th Jt. Work. New Technol. Comput. Assist.
Surg., no. October 2014, pp. 131–134, 2014, doi: 10.13140/RG.2.1.3972.9124.
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

25

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

5. M. Hamad, N. Mansfeld, S. Abdolshah, and S. Haddadin, “The Role of Robot
Payload in the Safety Map Framework,” IEEE Int. Conf. Intell. Robot. Syst.,
pp. 195–200, 2019, doi: 10.1109/IROS40897.2019.8968022.
6. O. D. Yirmibeşoğlu, T. Oshiro, G. Olson, C. Palmer, and Y. Mengüç,
“Evaluation of 3D printed soft robots in radiation environments and comparison
with molded counterparts,” Front. Robot. AI, vol. 6, no. MAY, pp. 1–14, 2019,
doi: 10.3389/frobt.2019.00040.
7. O. D. Yirmibesoglu et al., “Direct 3D printing of silicone elastomer soft
robots and their performance comparison with molded counterparts,” 2018
IEEE Int. Conf. Soft Robot. RoboSoft 2018, pp. 295–302, 2018, doi: 10.1109/
ROBOSOFT.2018.8404935.
8. I. De Falco, G. Gerboni, M. Cianchetti, and A. Menciassi, “Design and
Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally
Invasive Surgery,” J. Vis. Exp., no. 105, pp. 1–9, 2015, doi: 10.3791/53118.
9. T. Ranzani, M. Cianchetti, G. Gerboni, I. De Falco, and A. Menciassi, “A
Soft Modular Manipulator for Minimally Invasive Surgery: Design and
Characterization of a Single Module,” IEEE Trans. Robot., vol. 32, no. 1, pp.
187–200, 2016, doi: 10.1109/TRO.2015.2507160.
10. K. M. de Payrebrune and O. M. O’Reilly, “On constitutive relations for a rodbased model of a pneu-net bending actuator,” Extrem. Mech. Lett., vol. 8, pp.
38–46, Sep. 2016, doi: 10.1016/J.EML.2016.02.007.
11. Z. Wang, R. Kanegae, S. Hirai, and W. E. T. Al, “Circular Shell Gripper
for Handling Food Products,” vol. 00, no. 00, pp. 1–13, 2020, doi: 10.1089/
soro.2019.0140.
12. L. Marechal, P. Balland, L. Lindenroth, F. Petrou, C. Kontovounisios, and F.
Bello, “Toward a Common Framework and Database of Materials for Soft
Robotics,” Soft Robot., vol. 00, no. 00, 2020, doi: 10.1089/soro.2019.0115.
13. M. Manns, J. Morales, and P. Frohn, “Additive manufacturing of silicon based
PneuNets as soft robotic actuators,” 2018, doi: 10.1016/j.procir.2018.03.186.
14. F. Schreiber, M. Manns, and J. Morales, “Design of an additively manufactured
soft ring-gripper,” Procedia Manuf., vol. 28, pp. 142–147, Jan. 2019, doi:
10.1016/J.PROMFG.2018.12.023.
15. S. Rosset, O. A. Araromi, S. Schlatter, and H. R. Shea, “Fabrication Process
of Silicone-based Dielectric Elastomer Actuators,” J. Vis. Exp., no. 108, pp.
1–13, 2016, doi: 10.3791/53423.
16. P. Abbasi, M. A. Nekoui, M. Zareinejad, P. Abbasi, and Z. Azhang, “Position
and Force Control of a Soft Pneumatic Actuator,” Soft Robot., vol. 00, no. 00,
pp. 1–14, 2020, doi: 10.1089/soro.2019.0065.
17. D. Rus and M. T. Tolley, “Design, fabrication and control of soft robots,” Nature,
vol. 521, no. 7553, pp. 467–475, 2015, doi: 10.1038/nature14543.
18. A. Raatz, S. Blankemeyer, G. Runge, C. Bruns, and G. Borchert, “Opportunities
and Challenges for the Design of Inherently Safe Robots,” in Soft Robotics:
Transferring Theory to Application, A. Verl, A. Albu-Schäffer, O. Brock,
and A. Raatz, Eds. Berlin, Heidelberg: Springer Berlin Heidelberg, 2015, pp.
173–183.

26

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�An agile multi-body additively manufactured soft actuator for soft manipulators / Jorge Morales, et al.

19. P. Polygerinos et al., “Towards a soft pneumatic glove for hand rehabilitation,”
IEEE Int. Conf. Intell. Robot. Syst., pp. 1512–1517, 2013, doi: 10.1109/
IROS.2013.6696549.
20. B. Mosadegh et al., “Pneumatic networks for soft robotics that actuate
rapidly,” Adv. Funct. Mater., vol. 24, no. 15, pp. 2163–2170, 2014, doi:
10.1002/adfm.201303288.
21. J. A. Lenssen, H. Naghibi, and M. Abayazid, “Evaluation of design
aspects of modular pneumatic soft robotic endoscopes,” RoboSoft 2019
- 2019 IEEE Int. Conf. Soft Robot., pp. 56–61, 2019, doi: 10.1109/
ROBOSOFT.2019.8722749.
22. J. Z. Gul et al., “3D printing for soft robotics–a review,” Sci. Technol. Adv.
Mater., vol. 19, no. 1, pp. 243–262, 2018, doi: 10.1080/14686996.2018.143
1862.
23. M. Pérez, D. Carou, E. M. Rubio, and R. Teti, “Current advances in additive
manufacturing,” Procedia CIRP, vol. 88, pp. 439–444, 2020, doi: 10.1016/
j.procir.2020.05.076.
24. T. B. Tuli and M. Manns, “Hierarchical motion control for real time simulation
of industrial robots,” in CIRP Manufacturing Systems Conference 2019, 2019,
vol. 00.
25. K. W. A.B. Spierings, M. Voegtlin, T. Bauer, “Materials Testing Standards
for Additive Manufacturing of Polymer Materials :,” Prog Addit Manuf, vol.
1, pp. 9–20, 2015, doi: http://dx.doi.org/10.6028/NIST.IR.8059.
26. H.-T. Lin et al., “Softworms: the design and control of non- pneumatic, 3Dprinted, deformable robots Recent citations Softworms: the design and control
of non-pneumatic, 3D-printed, deformable robots,” Bioinspir. Biomim, vol.
11, 2016, doi: 10.1088/1748-3190/11/2/025001.
27. D. M. App, “Motion Terminal VTEM,” pp. 1–36, 2019.
28. K. M. de Payrebrune and O. M. O’Reilly, “On constitutive relations for a
rod-based model of a pneu-net bending actuator,” Extrem. Mech. Lett., vol.
8, no. 10, pp. 38–46, 2016, doi: 10.1016/j.eml.2016.02.007.
29. S. Ibrahim, J. C. Krause, and A. Raatz, “Linear and nonlinear low level control of
a soft pneumatic actuator,” RoboSoft 2019 - 2019 IEEE Int. Conf. Soft Robot.,
vol. V, pp. 434–440, 2019, doi: 10.1109/ROBOSOFT.2019.8722737.
30. Z. Gong et al., “An opposite-bending-and-extension soft robotic manipulator
for delicate grasping in shallow water,” Front. Robot. AI, vol. 6, no. APR,
pp. 1–10, 2019, doi: 10.3389/frobt.2019.00026.

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

27

�Imágenes fotoacústicas para
diagnósticos médicos
B

RESUMEN
Este artículo presentan algunos de los aspectos más sobresalientes de la
investigación y desarrollo de la acústica subacuática, así como reconoce el
mérito de miembros de la Sociedad Americana de Acústica (Acoustics Society
of America, ASA), quienes contribuyeron con su trabajo durante el período de la
Segunda Guerra Mundial. Los resultados de tal trabajo se convirtieron en logros
científicos y de ingeniería que aparecen en literatura sobre acústica.
PALABRAS CLAVE
Sociedad Americana de Acústica, sonar, detección submarina.
ABSTRACT
This paper presents some of the highlights about research and development
of sub-aquatic acoustics, as well as it gives recognition to the members of the
Acoustical Society of America (ASA), who contributed with their work along
the Second World War. The results of such work have turned into scientific and
engineering achievements, which are published in literature about acoustics.
KEYWORDS
Acoustic Society of America, sonar, submarine detection.
Introducción
La imagen fotoacústica tiene el potencial de proporcionar el diagnóstico no
invasivo de numerosas enfermedades frecuentes, en tiempo real, debido a la
capacidad única de la tecnología para visualizar cambios moleculares profundos
dentro del tejido vivo con resolución espacial comparable al ultrasonido. La
imagen fotoacústica es una técnica de imagen híbrida que combina la capacidad
de contraste y la sensibilidad espectral de la imagen óptica con la resolución
y la capacidad de penetración en el tejido del ultrasonido. Durante el proceso
de obtención de imágenes fotoacústicas, los materiales absorben la energía de
la luz y convierten la luz en calor mediante la relajación no radiativa. Cuando
los materiales se calientan, se expanden en tamaño debido a sus propiedades
termoelásticas, que generan una onda de presión. Estas ondas pueden propagarse
a través del entorno circundante para ser detectadas en la superficie. Este efecto
es familiar para cualquiera que haya experimentado una tormenta de verano, un

28

Traducción al español con la colaboración de Leonardo Treviño Arrambide y Daniela Alejandra Gutiérrez Dimas.

Departamento de Ingeniería Biomédica
Departamento de Ingeniería Eléctrica y Computación
C
Departamento de Ingeniería Biomédica y Computación
Universidad de Texas en Austin Austin, Texas 78712
carolynb@tulane.edu
A

“Photoacoustic imaging for medical diagnostics. Vol. 8, Issue 4, 2012. ”.
https://acousticstoday.org/photoacoustic-imaging-for-medical-diagnostics-carolyn-l-bayer/
Reproduced with permission from Acoustics Today (www.acousticstoday.org). Copyright 2012, Acoustical Society of America.

Carolyn L. BayerA, Geoffrey P. LukeB, Stanislav Y. EmelianovC

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

rayo calienta rápidamente el aire, resultando en que éste se expande y genera un
trueno audible. En general, el calentamiento induce la expansión del material
(por ejemplo el efecto termoacústico) podría ser causado por muchas formas de
transferencia de energía, pero el término “fotoacústica” especifica la conversión
de luz en calor, resultando en la generación de ondas sonoras características.
El efecto fotoacústico fue descubierto por primera vez por Alexander
Graham Bell en 1880.1 A partir de sus experimentos dedujo que una luz brillante
intermitente podría calentar ópticamente materiales absorbentes, causando la
expansión del material de una manera que genere ondas vibratorias audibles.
Bell demostró que las fibras más oscuras producen sonidos más fuertes que las
fibras más claras, un principio que es consistente con la relación fotoacústica
general en uso hoy en día, la amplitud de la señal fotoacústica generada es
proporcional a la cantidad de luz absorbida. Bell también mostró, al separar la
luz blanca con un prisma, ciertas combinaciones de color de la luz y las fibras
podrían generar un sonido más fuerte. Hoy la imagen fotoacústica de longitudes
de onda múltiples utiliza este mismo principio, cambiando la longitud de onda
de la luz y correlacionando la amplitud de la respuesta fotoacústica con los
espectros de absorción de los materiales que se están fotografiando.
Una aplicación moderna del efecto fotoacústico es la generación de imágenes
médicas de cromóforos biológicos típicamente presentes en el tejido, que
pueden absorber la energía de la luz resultando en la generación de transitorios
fotoacústicos. Las ondas de presión fotoacústica pueden ser recibidas por
transductores de ultrasonido en la superficie externa del tejido, haciendo que
la imagen fotoacústica sea un método de imagen médica no invasivo y no
ionizante capaz de resolución similar al ultrasonido, a una profundidad de tejido
significativa. Las imágenes médicas fotoacústicas se propusieron por primera
vez a mediados de la década de 1990, 2,3 y los reportes iniciales sobre el uso del
efecto fotoacústico para imágenes de animales vivos se publicaron nueve años
después. Hoy existen muchas demostraciones in vivo de imágenes fotoacústicas
de aplicaciones biomédicas relevantes para el diagnóstico médico, incluyendo
cáncer,5,6 función vascular cerebral,7-9 y cardiovasculares,10 e ingeniería de
soporte de tejido, 11,12 impulsando avances traslacionales en imagen clínica
fotoacústica.13
Mientras que los métodos de imagen médica existentes, incluyendo el
ultrasonido, son capaces de producir imágenes de lo que está debajo de la piel,
la mayoría de ellos proporcionan contraste entre las características anatómicas
dentro del tejido. Por ejemplo, la diferencia en la impedancia acústica entre
el tejido blando y un tumor proporcionan contraste dentro de una imagen de
ultrasonido. Aunque la anatomía es crítica para entender la imagen, en muchas
enfermedades la anatomía por sí sola no se puede utilizar para dar un diagnóstico
determinado de manera concluyente. En cambio, las propiedades fisiológicas y
bioquímicas del sistema influyen en la progresión de la enfermedad y, por tanto,
en el pronóstico del paciente. Se requieren capacidades de imagen funcional para
proporcionar información fisiológica, mientras que la información bioquímica
puede ser proporcionada por imágenes moleculares. En comparación con el
ultrasonido, la imagen fotoacústica proporciona capacidades mejoradas para
la imagen funcional y molecular. Por ejemplo, la saturación de oxígeno en la
sangre, una importante propiedad funcional relevante para muchos procesos de
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

29

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

enfermedad, puede evaluarse mediante fotoacústica.7 La imagen fotoacústica
también puede proporcionar información molecular mediante el uso de una sonda
o un trazador, que puede ser utilizada para generar el contraste necesario para
producir una imagen.14 Debido al potencial para realizar imágenes funcionales
y moleculares in vivo no invasivas en tiempo real, la imagen fotoacústica se está
aplicando cada vez más como método clínico y preclínico destinado a mejorar
el diagnóstico médico.
ANTECEDENTES
En un sistema de imagen fotoacústica contemporáneo, se utiliza un láser
pulsado de nanosegundos para generar ondas de presión transitoria, que son
recibidas por un transductor de ultrasonido y procesada para formar imágenes
de tejido biológico (figura 1).
En una configuración típica, el pulso de luz emitido por el láser va acompañado
de una señal de disparo enviada al hardware del sistema de imagen, coordinando

Fig. 1. Instrumentación y componentes principales de procesamiento que comprenden
un sistema combinado de ultrasonido y fotoacústica. La señal fotoacústica, generada
por la absorción óptica de energía láser por la muestra, se recibe por un transductor de
ultrasonido, formada y procesada para formar una imagen fotoacústica. El transductor
emite el ultrasonido, adecuadamente formado por haces, y el ultrasonido reflejado es
recibido, formado por rayos y procesado para formar la imagen de ultrasonido.

la adquisición de la señal fotoacústica. Después de la emisión del pulso láser,
las señales fotoacústicas generadas por los absorbentes ópticos dentro del
campo de visión son recogidas por el transductor (figura 2). Al igual que con el
ultrasonido, el momento en que se recibe la señal fotoacústica está relacionado
con la profundidad del objeto absorbente dentro de la muestra por la velocidad
del sonido en el tejido.
Los sistemas multimodales, combinando ultrasonido y fotoacústica, aplican
un retardo de tiempo (τPA) después de la señal de disparo láser, como se muestra
en la figura 2, después del cual la señal de ultrasonido es transmitida y recibida
para ser procesada utilizando técnicas usuales. Debido a las similitudes en el
hardware del sistema y el diseño de procesamiento entre la imagen fotoacústica

30

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

Fig. 2. Generación de señales fotoacústicas y ultrasónicas. (a) El pulso láser es dispersado
y absorbido por la muestra. (b) La absorción que conduce al calentamiento genera una
onda de presión transitoria que es recibida por el transductor. (c) Después de un retraso,
τPA, el ultrasonido se transmite y recibe durante el período de tiempo 2• τPA.

y la ecografía, un sistema de ultrasonido existente puede ser modificado para
adquirir señales fotoacústicas sin más esfuerzo que mediante la adición de una
fuente de luz pulsada, realizando modificaciones menores de hardware para
programar adecuadamente las señales transmitidas y recibidas, y modificar la
interfaz de usuario del software y los métodos de procesamiento de señales.
Varias compañías están comercializando sistemas fotoacústicos integrados para
imágenes de animales pequeños, mostrados en la figura 3, y es probable que
pronto entren más en el mercado (dato de 2012). Estos sistemas se dividen en
dos categorías diseñadas para utilizar un escáner de ultrasonido lineal traducible
con el formado del haz de retardo y suma, o un conjunto fijo de transductores
con reconstrucción de imágenes de tomografía computarizada.
Los sistemas de escaneo fotoacústico lineal producen una visión bidimensional
(2D) de una sola proyección, y luego se escanean en una tercera dimensión, un
método de imagen volumétrica análogo a los sistemas de ultrasonido clínicos no
invasivos de uso común, donde se barre manualmente a lo largo de la superficie
del tejido con un arreglo de transductores. Los sistemas tomográficos utilizan
una serie de transductores, a menudo colocados en un anillo alrededor del
objeto que se está fotografiando, y luego usan algoritmos de reconstrucción para
reproducir la imagen. Visual Sonics Inc. comercializa el Vevo LAZR (Figura
3a), que utiliza su pequeña plataforma de ultrasonido animal de alta resolución
(Vevo 2100) en combinación con un láser pulsado nanosegundo sintonizable.
Cuando la imagen de cuerpo entero es una prioridad, el sistema de tomografía
optoacoustica multiespectral (Figura 3b), producido por iThera Medical, guía
el haz láser para iluminar un anillo de luz alrededor del animal que está siendo
fotografiado, y luego se mueve en la tercera dimensión para adquirir imágenes
volumétricas. 15 El Nexus 128 (Figura 3c), producido por Endra, proporciona un
sistema fotoacústico tomográfico alternativo. Todos estos sistemas consisten en
una fuente de láser sintonizable que proporciona luz infrarroja cercana (NIR)
aproximadamente entre 680 y 970 nm. La elección de un sistema de exploración
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

31

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

Fig. 3. Sistemas de imagen fotoacústica preclínica disponibles en el mercado.

o tomografía depende en gran medida de la aplicación. El usuario debe considerar
la resolución alcanzable, que depende de la frecuencia central y el ancho de banda
del transductor, el formador del haz o algoritmos de reconstrucción implementada,
y también la sensibilidad alcanzable, que está influenciado por la fluencia de
la luz y la distribución entregada dentro del tejido. Un sistema de escaneo por
ultrasonido generalmente será más flexible, acomodando una variedad de tipos de
animales, y potencialmente proporcionando múltiples matrices de transductores
optimizados para diferentes profundidades de escaneo. Un sistema de imagen
fotoacústica basado en una plataforma de escáner de ultrasonido proporciona
técnicas adicionales de imagen funcional (como el modo Doppler de ultrasonido)
para proporcionar información anatómica y funcional. En contraste, los sistemas
tomográficos son capaces de adquirir datos volumétricos en un tiempo más corto,
y tienen menos ruido en forma de mota fotoacústica debido a la distribución
espacial del anillo transductor. Sin embargo, las aplicaciones clínicas de un
sistema de tomografía fotoacústica serán limitadas, con una notable excepción;
la imagen tomográfica fotoacústica del tejido mamario.16
Mientras que los absorbentes ópticos que se encuentran de forma natural en
el cuerpo, como la hemoglobina, los lípidos y la melanina, pueden utilizarse para
generar imágenes ópticas, el uso de agentes de contraste de imagen de tamaño
nanométrico permiten que la imagen fotoacústica se vuelvan verdaderamente
“molecular” en el metodo de imagen in vivo.17,18 El contraste fotoacústico
puede mejorarse mediante el uso de fragmentos moleculares o nanopartículas
sintetizadas químicamente. Las nanopartículas inorgánicas son de especial
interés, debido a su flexibilidad con respecto a la forma, tamaño y química de
la superficie. Estas características se pueden optimizar para mejorar la entrega
de las nanopartículas al tejido de interés, como los tumores cancerosos.19 Si la
superficie de nanopartículas es modificada mediante la adición de un medio capaz
de ser dirigido, estos agentes se vuelven agentes de imagen molecular, dado que
las nanopartículas blanco deberían retenerse preferentemente dentro de la región
del tejido que expresa el objetivo. Además, las nanopartículas metálicas de oro o
plata, hay varios ejemplos, que se muestran en la figura 4, tienen resonancia de
plasmón superficial, lo que significa que los electrones de valencia de los átomos
oscilan colectivamente a una frecuencia característica.

32

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

Fig. 4. Imágenes de microscopía electrónica de transmisión de nanopartículas metálicas
plasmónicas que se han utilizado para la obtención de imágenes fotoacústicas in vivo.
(a) Nanoesferas de oro; b) Nanoplacas de plata; c) Nanovarillas de oro recubiertas de
sílice. Barras de escala = 100 nm.

Cuando la luz incidente está en la misma frecuencia que la resonancia de
plasma de superficie, esa luz es absorbida muy eficientemente y convertida en
calor, haciendo de las nanopartículas metálicas excelentes agentes de contraste
para la imagen fotoacústica. Las nanopartículas que se dirigen molecularmente
se pueden arreglar para su entrega a tejidos particulares en función del tamaño,
la forma y las propiedades de la superficie, mientras que la alta absorción óptica
de nanopartículas metálicas genera una fuerte señal fotoacústica y proporciona
un alto contraste con el tejido circundante. Mediante el uso de nanopartículas
metálicas, también podemos ajustar sus propiedades de absorción óptica para
aprovechar la “ventana óptica de tejido”. Dentro de esta región de longitud de
onda, entre aproximadamente 600 nm a 1300 nm, la absorción óptica del tejido
nativo es relativamente baja, por lo que la luz puede penetrar más profundamente
en el tejido, permitiendo la adquisición de imágenes fotoacústicas a profundidades
de tejido significativamente mayores. Mediante imágenes en longitudes de onda
que no son altamente absorbidas en los tejidos, el efecto fotoacústico puede
utilizarse para generar imágenes moleculares de alta resolución in vivo a una
profundidad de tejido significativa. Sigue habiendo dudas sobre la seguridad de las
nanopartículas metálicas para su uso en el cuerpo humano.20,21 De hecho, todavía
se desconoce mucho sobre su toxicidad a corto y a largo plazo, pero muchos
grupos están estudiando estos efectos,21 y tres estudios clínicos de metodologías
basadas en nanopartículas de oro para el tratamiento del cáncer están en marcha
o se han completado.22 Además, la obtención de imágenes fotoacústicas podría
contribuir a mejorar la comprensión de los mecanismos de biodistribución y
aclaramiento que afectan a la toxicidad de las nanopartículas.

Diagnóstico de imágenes fotoacústicas

En nuestros estudios, la información anatómica, funcional y molecular
se adquirió utilizando una combinación de ultrasonido y de imágenes
multilongitud de onda de ratones in vivo portadores de tumores cancerosos.
Todos los métodos siguen protocolos aprobados por el Comité Institucional
de Cuidado y Uso de Animales de la Universidad de Texas en Austin.
Primero, desarrollamos un pequeño modelo animal de cáncer de mama que
consistía en dos tumores establecidos a partir de líneas celulares de cáncer
de mama humano con expresión de biomarcador de células diferenciales.
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

33

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

Para este pequeño modelo animal, iniciamos tumores dentro de la almohadilla
de grasa mamaria usando inyecciones de células cancerosas BT-474, que
sobreexpresan el receptor celular HER2, y células cancerosas MDA-MB-231, que
sobre-expresan la integrina αvβ3, presente en la superficie celular de las células
epiteliales de neovasculatura. Las nanovarillas de oro fueron elegidas como
el agente de contraste molecular ya que, además de ser altamente absorbente,
ópticamente, debido a los efectos de resonancia de plasma de superficie, sus
espectros de absorción óptica pueden sintonizarse cambiando su relación de
aspecto.23 Sintonizando nanovarillas para tener diferentes longitudes de onda
de absorción óptica de pico, es posible distinguir entre múltiples agentes de
contraste nanovarilla a través de imágenes fotoacústicas de longitudes de onda
múltiples.24 Recubrimos las nanovarillas con sílice amorfa, lo que mejora la
estabilidad térmica de la nanovarilla de oro 25 y la eficiencia de generación de
señales fotoacústicas.26 Sílice-nanovarillas recubiertas con dos relaciones de
aspecto diferentes fueron modificados químicamente para fijar anticuerpos de
orientación, lo que permite que la nanopartícula sea absorbida preferentemente
por las células tumorales.24 Los agentes de contraste se inyectaron en el torrente
sanguíneo de un ratón que hacía crecer los tumores. Los agentes de contraste
inyectados se distribuyen a través del sistema circulatorio, y se infiltran a través
de los tejidos del ratón, incluyendo los tumores cancerosos.
La región tumoral del ratón fue fotografiada usando un escáner de ultrasonido
animal pequeño de alta frecuencia Vevo 2100 (Visualsonics Inc.), integrado con
un láser pulsado nanosegundo Spectraphysics Quantaray Pro Nd:YAG con un
oscilador paramétrico óptico GWU Premiscan (OPO) para sintonizar la longitud
de onda de la luz. Se utilizó un haz de fibra óptica para entregar la luz láser
a ambos lados de un conjunto de transductores lineales. El sistema se utilizó
para entregar entre 10-20 mJ/cm2 de luz en un rango de longitudes de onda de
680-930 nm. Un transductor de ultrasonido de 21 MHz (MS250, Visualsonics
Inc.) recogió las señales fotoacústicas en cada longitud de onda, seguido de la
transmisión de ultrasonido y la recepción del ultrasonido reflejado por el mismo
transductor, dando lugar a imágenes de ultrasonidos y fotoacústicas registradas
conjuntamente. Se utilizó un motor de paso lineal para traducir la construcción
del transductor y del haz de fibra, en pasos de 150 µm, para adquirir imágenes
fotoacústicas y de ultrasonido en la tercera dimensión, promediando cuatro
señales fotoacústicas en cada paso. El ultrasonido tridimensional (3D) y las
imágenes fotoacústicas fueron capturadas en un volumen que rodeaba los dos
tumores dentro de la almohadilla de grasa mamaria del ratón.
La amplitud de la señal fotoacústica recibida depende de la longitud de onda
de la luz láser utilizada para iluminar la muestra. Esta dependencia puede ser sin
mezclar en los espectros de absorción individuales de los absorbentes dentro del
tejido oxyhemoglobina, deoxihemoglobina, nanopartículas 1 y nanopartículas
2. Se utilizó un método lineal de error espectral mínimo cuadrado en el que se
suponía que cada voxel contenía una combinación de los cuatro absorbentes
ópticos.27 En este método, la señal fotoacústica inicial, situado en una
posición dentro de la imagen, depende de la concentración de los absorbentes
en la región, la fluencia láser, y el parámetro Grüneisen.28 Los espectros de
absorción óptica de hemoglobina se obtuvieron de la literatura29 y los espectros
de nanopartículas se midieron utilizando UV-Espectroscopia de Vis (lector de

34

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

microplacas Synergy HT, Biotek Instruments, Inc.). Si el problema espectral
separa está sobreentrenado, que se logra adquiriendo datos fotoacústicos en
más longitudes de onda que el número de absorbedores presentes en el tejido,
entonces se puede obtener una estimación de error cuadrado medio mínimo
para las concentraciones del absorbente. Las concentraciones estimadas de
desoxihemoglobina, oxihemoglobina, nanopartículas 1 y nanopartículas 2 se
muestran usando colormaps azul, rojo, verde y violeta, respectivamente. Para
separación espectral, los datos fueron promediados en voxels de tamaño 500 µm
200 µm 300 µm. Las imágenes de los absorbedores ópticos fueron superpuestas
en imágenes de ultrasonido en escala de grises para visualizar la anatomía en
la región.
Se generaron imágenes anatómicas 3D de alta resolución de la región
tumoral mediante el procesamiento de las señales de ultrasonido recibidas por
el sistema integrado de ultrasonido y de imagen fotoacústica (figura 5). En la
figura 5a, una imagen 3D de una sola longitud de onda de imagen fotoacústica,
superpuesta en la imagen de ultrasonido, muestra claramente la anatomía
dentro de la región de imágenes del ratón, incluyendo la vasculatura (en color,
proporcionada por la imagen fotoacústica), y la capa de piel y el fémur dentro de
la pierna (en escala de grises, proporcionada por la imagen de ultrasonido).En
nuestro modelo de ratón podemos identificar las regiones tumorales mediante
la localización de dos regiones hipoecoicas bajo la piel, como se muestra en la
ecografía 2D en la figura 5b. De la señal fotoacústica (figuras 5c y 5d), está claro
que hay absorbentes de luz dentro de la piel, absorción de luz de la vasculatura
que rodea los tumores, y de los propios tumores. Si bien tanto el ultrasonido
como las imágenes fotoacústicas indican la presencia de tumores, las imágenes
anatómicas por sí solas no proporcionan información suficiente para diagnosticar
la malignidad, ya que la precisión del ultrasonido en la distinción de tumores
benignos y malignos es insuficiente.30

Fig. 5. Imágenes anatómicas fotoacústicas y ecográficas in vivo. (a) Superposición
3D de imágenes fotoacústicas y de ultrasonido de la parte superior de la pierna/
región abdominal. La caja azul muestra el plano de imagen 2D de (b-d). (b) Imagen
ecográfica que muestra dos tumores hipoecoicos. (c) Imagen fotoacústica, adquirida
utilizando una longitud de onda láser de 850 nm. (d) Superposición de imágenes
fotoacústicas y ultrasónicas. Barras de escala = 2 mm.
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

35

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

Mientras que el ultrasonido in vivo y las imágenes fotoacústicas de longitud de
onda única en la figura 5 proporcionan información anatómica de alta resolución,
se desconoce la composición celular del tumor, y por lo tanto somos incapaces,
en esta etapa de la imagen, para identificar las características funcionales o la
expresión molecular celular, que podría ayudar en la identificación de un tumor
benigno canceroso.
Las imágenes fotoacústicas funcionales, por ejemplo la saturación de oxígeno
en la sangre del tumor, podrían proporcionar criterios adicionales para evaluar
la función tumoral. Adquirimos información funcional mediante la detección
de señales fotoacústicas en múltiples longitudes de onda láser y la destrucción
espectral de las señales como se describe anteriormente. Para la obtención de
imágenes funcionales del modelo animal descrito anteriormente, adquirimos
señales fotoacústicas generadas por luz láser entre 680-850 nm. Como se muestra
en la figura 6, podemos observar la saturación de oxígeno de la sangre dentro del
tejido normal y dentro de las regiones tumorales. Las concentraciones estimadas
de desoxihemoglobina y oxihemoglobina se muestran usando una escala de
color que va desde azul (0% saturación de oxígeno) a rojo (100% saturación de
oxígeno). La imagen 3D que se muestra en la figura 6a indica la distinción del
flujo venuo del flujo arterial dentro de la vasculatura del tejido de la imagen.
Mientras que el estudio de la vasculatura tiene relevancia para algunos nichos de
diagnósticos médicos, más significativamente, podemos utilizar la información
funcional proporcionada por la imagen fotoacústica multilongitud de onda para
estudiar la saturación de oxígeno en la sangre del tumor.

Fig. 6. Imagen funcional in vivo de la saturación de oxígeno en sangre. (a) Superposición
3D de porcentaje de saturación de oxígeno en sangre, determinada a partir de la
destrucción espectral de la señal fotoacústica multilongitud de onda, y la imagen
de ultrasonido. El volumen es de 23 mm (ancho) x 6 mm (alto) x 7 mm (dirección
escaneada). (b) 2D rebanada del porcentaje de saturación de oxígeno en sangre y la
señal de ultrasonido. La flecha negra indica una región hipóxica dentro de un tumor.
Barras de escala = 2mm.

36

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

Los tumores malignos hipóxicos tienen un pronóstico peor, lo que hace que
la saturación de oxígeno en la sangre sea útil para la evaluación del tratamiento
y la respuesta terapéutica.31 Como se muestra en la figura 6b, hay una región
hipóxica dentro del núcleo del tumor fotografiado. Esta menor saturación de
oxígeno es probable debido a la alta actividad metabólica de las células ubicadas
dentro de esa región, lo que lleva a una entrega insuficiente de oxígeno dentro del
tumor. La imagen fotoacústica funcional de la saturación de oxígeno en sangre
podría utilizarse para estudiar la respuesta del tumor al tratamiento terapéutico,
no invasivo, en tiempo real y durante largos períodos de crecimiento tumoral.
Por último, podemos seguir procesando las imágenes fotoacústicas para ver
la señal que se correlaciona con los espectros de absorción óptica de los agentes
de contraste inyectados. En los estudios que se muestran aquí, hemos utilizado
nanovarillas de oro recubiertas de sílice, pero es importante señalar que una
gran variedad de agentes de contraste se pueden utilizar con éxito para la
imagen fotoacústica molecular; 32 imágenes fotoacústicas in vivo con contraste
mejorado se ha demostrado con el azul de metileno de color aprobado por la
FDA,33 con nanoesferas de oro,27 o con nanoplacas de plata.34 Como se muestra
en la figura 7, dentro de nuestro modelo de ratón, las regiones de acumulación
de nanopartículas corresponden a las regiones tumorales identificadas con la
ecografía y la imagen fotoacústica funcional de la saturación de oxígeno en
sangre. Con el tiempo, hay un aumento en la señal atribuida a los agentes
de contraste de nanopartículas dentro de la región tumoral (figuras 7b y 7c).
La acumulación de nanopartículas podría deberse a dos efectos. Se sabe que
los tumores tienen vasculatura con fugas, lo que permite una mayor entrega
de partículas de tamaño nano a través del efecto mejorado de permeabilidad
y retención. Además, las nanopartículas inyectadas fueron bioconyugadas
a anticuerpos específicos para receptores celulares sobre expresados sobre
tipos celulares utilizados para iniciar los tumores, por lo que es probable que
el objetivo activo mejore la retención de las nanopartículas específicas dentro
de la región tumoral. Este ejemplo demuestra cómo el uso de nanopartículas
puede proporcionar información molecular sobre la expresión celular del tumor.

Fig. 7. Imagen molecular in vivo de la acumulación de agentes de contraste dentro de un
tumor dirigido. La señal fotoacústica de longitudes de onda múltiples se mezcló en dos
componentes correspondientes a dos agentes de contraste diferentes, nanopartículas
1 (NP1) y nanopartículas 2 (NP2). (a) Superposición 2D de imagen de ultrasonido,
distribución de NP1 y NP2 antes de la inyección del agente de contraste, mostrando una
señal fotoacústica de fondo mínima. La acumulación de NP1 y NP2 dentro del tumor
se muestra (b) 8 horas y (c) 24 horas después de la inyección intravenosa. Barras de
escala = 1 mm.

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

37

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

De esta manera, la fotoacústica combina los beneficios de la resolución óptica
de alto contraste de las sondas de interacción luminosa, con las capacidades de
profundidad de imagen del ultrasonido.

Conclusiones

La fortaleza de la imagen fotoacústica está en su capacidad hacer imagenes de
cambios funcionales y moleculares, a una profundidad de tejido significativa, en
animales vivos. Los investigadores acaban de empezar a explotar las técnicas de
imagen fotoacústica para emprender nuevos descubrimientos de las características
funcionales y moleculares del cáncer, las enfermedades cardiovasculares y las
enfermedades neurológicas. Concebimos la imagen fotoacústica como una
herramienta crítica en el diagnóstico médico y la terapia guiada por imágenes
en el futuro. Mientras que la mayoría de las aplicaciones de imagen funcional
fotoacústica hasta ahora han utilizado fuentes de contraste que están presentes
naturalmente, también es posible introducir agentes de contraste de activación
bioquímica para la imagen funcional. Por ejemplo, existen muchos pigmentos
que cambian su espectro de absorción óptica en base al pH, o en presencia
de una enzima. Al añadir un agente de contraste activable, podemos utilizar el
cambio en la intensidad de la señal fotoacústica de longitudes de onda múltiples
para proporcionar información cuantitativa sobre el entorno bioquímico dentro
de los tejidos, y monitorear los cambios en este entorno.
Mientras que este artículo se centra en la imagen, también es de notar que
existe una sinergia natural entre la imagen fotoacústica y la terapia. Por ejemplo,
la terapia térmica se puede lograr mediante el uso de una fuente de luz continua
para calentar los absorbedores ópticos utilizados para el contraste fotoacústico,
a una temperatura que puede conducir a la destrucción de las células y el
tejido circundante.35 Adicionalmente, Los agentes de contraste fotoacústicos
multimodales pueden diseñarse para proporcionar la entrega de moléculas
terapéuticas activadas por láser, por ejemplo, utilizando un recubrimiento de
polímero sensible a la temperatura,36 o utilizando el calor para liberar terapias
covalentes.37 La imagen fotoacústica no está exenta de limitaciones. Al igual que
el ultrasonido, la resolución estará limitada físicamente por la relación inversa
entre la profundidad de la imagen y la frecuencia del ultrasonido a medida que la
frecuencia aumenta, la resolución también aumenta, sin embargo la atenuación
de la señal es mayor en frecuencias más altas, lo que lleva a limitaciones en la
profundidad de la imagen. La sensibilidad se ve afectada por la dispersión de
la luz dentro del tejido, sin embargo nuevas técnicas para maximizar la señal al
ruido, incluyendo agentes de contraste mejorados, y variando las características
de la luz láser, pueden ayudar a minimizar la señal de fondo. Otras limitaciones
incluyen que el tiempo requerido para escanear el lograr una alta resolución
lateral depende de un haz estrecho, lo que significa que el transductor receptor
(en sistemas de escaneo) o el objeto que está siendo fotografiado (en sistemas
tomográficos) debe ser escaneado en una tercera dimensión para ampliar el
campo de visión. Esta limitación de tiempo limita la resolución temporal de la
información funcional y molecular que puede obtenerse a la escala de tiempo
de minutos. Actualmente, sólo existen en el mercado sistemas preclínicos
de obtención de imágenes fotoacústicas, pero la información funcional y
molecular adicional disponible a través de esta modalidad de obtención de

38

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

imágenes significará su creciente uso en estudios preclínicos, proporcionar los
antecedentes de investigación necesarios para las adaptaciones clínicas.
REFERENCIAS
1. 1. A. G. Bell, “On the production and reproduction of sound by light,” Am.
J. Sci. 20, 305-324 (1880).
2. R. A. Kruger “Photoacoustic ultrasound,” Med. Phys. 21, 127- 131 (1994).
3. A. A. Oraevsky, S. L. Jacques, R. O. Esenaliev, and F. K. Tittel “Time-resolved
optoacoustic imaging in layered biological tissues,” OSA Proc.Advances in
Optical Imaging and Photon Migration 21, 161-165 (1994).
4. X. Wang, Y. Pang, G. Ku, X. Xie, G. Stoica, and L. V. Wang “Noninvasive
laser-induced photoacoustic tomography for structural and functional in vivo
imaging of the brain,” Nature Biotechnol. 21, 803-806 (2003).
5. S. Mallidi, G. P. Luke, and S. Emelianov “Photoacoustic imaging in cancer
detection, diagnosis, and treatment guidance,” Trends in Biotechnol. 29, 213221 (2011).
6. J. Laufer, P. Johnson, E. Zhang, B. Treeby, B. Cox, B. Pedley, and P. Beard
“In vivo preclinical photoacoustic imaging of tumor vasculature development
and therapy,” J. Biomed. Optics 17, 056016-1 (2012).
7. E. W. Stein, K. Maslov, and L. V. Wang “Noninvasive, in vivo imaging of
blood-oxygenation dynamics within the mouse brain using photoacoustic
microscopy, ” J. Biomed. Optics 14, 020502- 020502 (2009).
8. J. Laufer, E. Zhang, G. Raivich, and P. Beard “Three-dimensional noninvasive
imaging of the vasculature in the mouse brain using a high resolution
photoacoustic scanner,” Appl.Optics 48, D299-306 (2009).
9. V. Tsytsarev, K. I. Maslov, J. Yao, A. R. Parameswar, A. V. Demchenko, and
L. V. Wang “In vivo imaging of epileptic activity using 2-nbdg, a fluorescent
deoxyglucose analog,” J. Neurosci. Methods 203, 136-140 (2012).
10. A. Taruttis, E. Herzog, D. Razansky, and V. Ntziachristos “Realtime imaging
of cardiovascular dynamics and circulating gold nanorods with multispectral
optoacoustic tomography,” Optics Express 18, 19592-19602 (2010).
11. X. Cai, B. S. Paratala, S. Hu, B. Sitharaman, and L. V. Wang “Multiscale
photoacoustic microscopy of single-walled carbon nanotube-incorporated
tissue engineering scaffolds,” Tissue Engineering Part C Methods 18, 310317 (2012).
12. S. Y. Nam, L. M. Ricles, L. J. Suggs, and S. Y. Emelianov “In vivo ultrasound
and photoacoustic monitoring of mesenchymal stem cells labeled with gold
nanotracers,” PLoS ONE 7, e37267 (2012).
13. D. Piras, W. Xia, W. Steenbergen, T. van Leeuwen, and S. G. Manohar
“Imaging breast lesions using the twente photoacoustic mammoscope:
Ongoing clinical experience,” Proc. SPIE 8223, 82231-82230C (2012).
14. G. P. Luke, D. Yeager, and S. Y. Emelianov “Biomedical applications of
photoacoustic imaging with exogenous contrast agents,” Ann. Biomed. Eng.
40, 422-437 (2012).

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

39

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

15. D. Razansky, A. Buehler, and V. Ntziachristos “Volumetric realtime
multispectral optoacoustic tomography of biomarkers,” Nature Protocols 6,
1121-1129 (2011).
16. R. A. Kruger, R. B. Lam, D. R. Reinecke, S. P. Del Rio, and R. P. Doyle
“Photoacoustic angiography of the breast,” Med. Phys. 37, 6096-6100
(2010).
17. A. Agarwal, S. W. Huang, M. O’Donnell, K. C. Day, M. Day, N. Kotov,
and S. Ashkenazi “Targeted gold nanorod contrast agent for prostate cancer
detection by photoacoustic imaging,” J. Appl. Phys. 102 (2007).
18. P.-C. Li, C.-R. C. Wang, D.-B. Shieh, C.-W. Wei, C.-K. Liao, C. Poe, S. Jhan,
A.-A. Ding, and Y.-N. Wu “In vivo photoacoustic molecular imaging with
simultaneous multiple selective targeting using antibody-conjugated gold
nanorods,” Optics Express 16, 18605-18615 (2008).
19. R. K. Jain, and T. Stylianopoulos “Delivering nanomedicine to solid tumors,”
Nature Reviews Clinical Oncol. 7, 653-664 (2010).
20. R. Goel, N. Shah, R. Visaria, G. F. Paciotti, and J. C. Bischof“Biodistribution
of tnf-alpha-coated gold nanoparticles in an in vivo model system,”
Nanomedicine 4, 401-410 (2009).
21. N. Khlebtsov, and L. Dykman “Biodistribution and toxicity of engineered gold
nanoparticles: A review of in vitro and in vivo studies,” Chem. Soc. Rev. 40,
1647-1671 (2011).
22. Clinicaltrials.gov [Internet] Bethesda: U.S. National Institutes of Health.
2000- [cited 2012 Sept 1]. Available from: http://www.clinicaltrials.gov/.
23. P. K. Jain, K. S. Lee, I. H. El-Sayed, and M. A. El-Sayed “Calculated
absorption and scattering properties of gold nanoparticles of different size,
shape, and composition: Applications in biological imaging and biomedicine,”
J. Phys. Chem. B 110, 7238-7248 (2006).
24. C. L. Bayer, Y. S. Chen, S. Kim, S. Mallidi, K. Sokolov, and S. Emelianov
“Multiplex photoacoustic molecular imaging using targeted silica-coated gold
nanorods,” Biomed. Optics Express 2, 1828-1835 (2011).
25. Y.-S. Chen, W. Frey, S. Kim, K. Homan, P. Kruizinga, K. Sokolov, and S.
Emelianov “Enhanced thermal stability of silica-coated gold nanorods for
photoacoustic imaging and image-guided therapy,” Optics Express 18, 88678878 (2010).
26. Y. S. Chen, W. Frey, S. Kim, P. Kruizinga, K. Homan, and S. Emelianov
“Silica-coated gold nanorods as photoacoustic signal nanoamplifiers,” Nano
Lett. 11, 348-354 (2011).
27. S. Kim, Y.-S. Chen, G. P. Luke, and S. Y. Emelianov “In vivo threedimensional spectroscopic photoacoustic imaging for monitoring nanoparticle
delivery,” Biomed. Optics Express 2, 2540-2550 (2011).
28. S. Kim, Y.-S. Chen, G. P. Luke, and S. Y. Emelianov “In vivo threedimensional spectroscopic photoacoustic imaging for monitoring nanoparticle
delivery,” Biomed. Optics Express 2, 2540-2550 (2011).
29. S. Prahl “Optical absorption of hemoglobin,” (Oregon Medical Laser Center)
(1999).

40

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Imágenes fotoacústicas para diagnósticos médicos / Carolyn L. Bayer, et al.

30. C. Sehgal, S. Weinstein, P. Arger, and E. Conant “A review of breast
ultrasound,” J. Mammary Gland Biology and Neoplasia 11, 113-123
(2006).
31. A. L. Harris “Hypoxia--a key regulatory factor in tumour growth,” Nature
Reviews Cancer 2, 38-47 (2002).
32. G. P. Luke, D. Yeager, and S. Y. Emelianov “Biomedical applications of
photoacoustic imaging with exogenous contrast agents,” Ann. Biomed. Eng.
40, 422-437 (2012).
33. K. H. Song, E. W. Stein, J. A. Margenthaler, and L. V. Wang “Noninvasive
photoacoustic identification of sentinel lymph nodes containing methylene
blue in vivo in a rat model,” J. Biomed. Optics 13, 054033 (2008).
34. K. A. Homan, M. Souza, R. Truby, G. P. Luke, C. Green, E. Vreeland,
and S. Emelianov “Silver nanoplate contrast agents for in vivo molecular
photoacoustic imaging,” ACS Nano 6, 641-650 (2012).
35. J.-W. Kim, E. I. Galanzha, E. V. Shashkov, H.-M. Moon, and V. P. Zharov
“Golden carbon nanotubes as multimodal photoacoustic and photothermal
high-contrast molecular agents,” Nature Nanotechnology 4, 688-694
(2009).
36. D. E. Owens, J. K. Eby, Y. Jian, and N. A. Peppas “Temperatureresponsive
polymer–gold nanocomposites as intelligent therapeutic systems,” J. Biomed.
Mat. Res. Part A 83A, 692-695 (2007).
37. W. F. Zandberg, A. B. S. Bakhtiari, Z. Erno, D. Hsiao, B. D. Gates, T.
Claydon, and N. R. Branda “Photothermal release of small molecules from
gold nanoparticles in live cells,” Nanomedicine 8, 908-915 (2012).

AGRADECIMIENTOS

Los autores reconocen el apoyo de los Institutos Nacionales de Salud (NIH)
en las subvenciones F32CA159913 (C.L. Bayer), y F31CA168168 (G.P. Luke).
Agradecemos a Juili Kevlar por proporcionar las imágenes TEM de nanovara de
oro recubierta de sílice, y al Dr. Kimberly Homan por proporcionar las imágenes
TEM de placa de plata. También agradecemos a Shailja Tewari de Visualsonics,
Christian Wiest de iThera Medical, y a Richard Moss de Endra Life Sciences por
proporcionar las imágenes compiladas en la figura 3.

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

41

�PHOTOACOUSTIC IMAGING FOR MEDICAL DIAGNOSTICS
Carolyn L. Bayer
Department of Biomedical Engineering, The University of Texas at Austin
Austin, Texas 78712

Geoffrey P. Luke
Department of Electrical and Computer Engineering, The University of Texas at Austin
Austin, Texas 78712

Stanislav Y. Emelianov
Departments of Biomedical and Electrical and Computer Engineering, The University of Texas at Austin
Austin, Texas 78712

materials being imaged.
Introduction
“Because of the potential
A modern application of the phohotoacoustic imaging has the
toacoustic
effect is the generation of
potential to provide real-time,
to perform real-time,
medical images of biological chronon-invasive diagnosis of numermophores typically present in tissue,
ous prevalent diseases, due to the technon-invasive in vivo
which can absorb light energy resulting
nology’s unique ability to visualize
in the generation of photoacoustic tranmolecular changes deep within living
functional and molecular
sients. The photoacoustic pressure
tissue with spatial resolution comparawaves
can be received by ultrasound
ble to ultrasound. Photoacoustic imagimaging, photoacoustic
transducers at the external surface of the
ing is a hybrid imaging technique that
combines the contrast capabilities and
imaging is increasingly being tissue, making photoacoustic imaging a
non-invasive, non-ionizing medical
spectral sensitivities of optical imaging
with the resolution and tissue penetraapplied as both a clinical and imaging method capable of resolution
similar to ultrasound, at significant tistion capabilities of ultrasound. During
sue depth. Photoacoustic medical imagthe photoacoustic imaging process,
preclinical method aimed
ing was first proposed in the midmaterials absorb light energy, and con1990s,2,3 and initial reports of using the
vert the light to heat via non-radiative
at improving medical
photoacoustic effect to image live anirelaxation. When materials heat, they
mals
were published nine years later.4
expand in size due to their thermoelasdiagnostics.”
Today, many in vivo demonstrations of
tic properties, which generates a presphotoacoustic imaging of biomedical applications relevant to
sure wave. These pressure waves can propagate through the
medical diagnostics exist, including cancer,5,6 brain vasculasurrounding environment to be detected at the surface. This
ture and function,7-9 cardiovascular,10 and tissue engineering
effect is familiar to everyone who has experienced a sumscaffolds,11,12 prompting translational advances in clinical
mer thunderstorm—lightning rapidly heats the air, resultphotoacoustic imaging.13
ing in the air expanding and generating audible thunder. In
While existing medical imaging methods, including
general, the heating which induces the expansion of the
ultrasound, are capable of producing remarkable images of
material (e.g., the thermoacoustic effect) could be caused by
what lies beneath our skin, most of these imaging methods
many forms of energy transfer, but the term “photoaprovide contrast between anatomical features within tissue—
coustic” specifies the conversion of light into heat, resulting
for example, the difference in acoustic impedance between
in the generation of characteristic sound waves.
soft tissue and a tumor provide contrast within an ultrasound
The photoacoustic effect was first discovered by
image. Though the anatomy is critical to understanding the
Alexander Graham Bell in 1880.1 His experiments deduced
image, in many diseases the anatomy alone cannot be used to
that an intermittent bright light could heat optically absorbindicate a particular diagnosis conclusively. Instead, the
ing materials, causing expansion of the material in a way that
physiological and biochemical properties of the system influgenerated audible vibrational waves. Bell demonstrated that
ence the disease progression, and therefore the prognosis of
darker fibers produced louder sounds than lighter fibers, a
the patient. Functional imaging capabilities are required to
principle which is consistent with the general photoacoustic
provide physiological information, while biochemical inforrelationship in use today—the amplitude of the generated
mation can be provided by molecular imaging. In compariphotoacoustic signal is proportional to the amount of
son to ultrasound, photoacoustic imaging provides improved
absorbed light. Bell also showed, by separating white light
capabilities for functional and molecular imaging. For examwith a prism, certain color combinations of light and fibers
ple, the blood oxygen saturation, an important functional
could generate a louder sound. Today, multiwavelength phoproperty relevant to many disease processes, can be assessed
toacoustic imaging uses this same principle, changing the
using photoacoustics.7 Photoacoustic imaging can also prowavelength of the light and correlating the amplitude of the
vide molecular information through the use of a probe or
photoacoustic response to the absorption spectra of the

P

Photoacoustic Imaging for Medical Diagnostics

15

�Fig. 1. Instrumentation and major processing components comprising a combined ultrasound and photoacoustic imaging system. Photoacoustic signal, generated by the optical absorption of laser energy by the sample, is received by an ultrasound transducer, beamformed and processed to form an photoacoustic image. Ultrasound, appropriately beamformed, is emitted by the transducer, and reflected ultrasound is received, beamformed and processed to form the ultrasound image.

tracer, which can be used to generate the needed contrast to
produce an image.14 Because of the potential to perform realtime, non-invasive in vivo functional and molecular imaging,
photoacoustic imaging is increasingly being applied as both a
clinical and preclinical method aimed at improving medical
diagnostics.

Background
In a contemporary photoacoustic imaging system, a
nanosecond pulsed laser is used to generate transient pressure waves, which are received by an ultrasound transducer
and processed to form images of biological tissue (Fig. 1). In
a typical set-up, the pulse of light emitted by the laser is
accompanied by a trigger signal sent to the imaging system
hardware, coordinating the acquisition of the photoacoustic

signal. After the laser pulse is emitted, the photoacoustic signals generated by the optical absorbers within the field of
view are collected by the transducer (Fig 2). As with ultrasound, the time at which the photoacoustic signal is received
is related to the depth of the absorbing object within the sample by the speed of sound in tissue.
Multimodal systems, combining ultrasound and photoacoustic imaging, apply a time delay (τPA) after the laser trigger signal, as shown in Fig. 2, after which the ultrasound signal is transmitted and received to be processed using customary techniques. Due to the similarities in system hardware and processing design between photoacoustic and
ultrasound imaging, an existing ultrasound system can be
modified to acquire photoacoustic signals with nominal
effort by adding a pulsed light source, making minor hard-

Fig. 2. Photoacoustic and ultrasound signal generation. (a) The laser pulse is scattered and absorbed by the sample. (b) Absorption which leads to heating generates a transient pressure wave which is received by the transducer. (c) After a delay, τPA, ultrasound is transmitted and received over the time period 2· τPA.
16

Acoustics Today, October 2012

�Fig. 3. Commercially available preclinical photoacoustic imaging systems.

ware modifications to appropriately time the transmitted and
received signals, and by modifying the software user interface and signal processing methods.
Several companies are marketing integrated photoacoustic systems for small animal imaging, shown in Fig. 3,
and it is likely that more will soon enter the market. These
systems fall into two categories—designed to use either a
translatable linear ultrasound scanner with delay-and-sum
beamforming, or a fixed array of transducers with computed tomography image reconstruction. Linear photoacoustic
scanning systems produce a two-dimensional (2D) view of
a single projection, and are then scanned in a third dimension – a volumetric imaging method analogous to commonly used non-invasive clinical ultr asound systems,
where a transducer array is manually scanned along the tissue surface. Tomographic systems use an array of transducers, often positioned in a ring around the object being
imaged, and then use reconstruction algorithms to reproduce the imaged slice. Visual Sonics Inc. markets the Vevo
LAZR (Fig. 3a), which uses their high resolution small animal ultrasound imaging platform (Vevo 2100) in combination with a tunable nanosecond pulsed laser. When whole
body imaging is a priority, the multispectral optoacoustic
tomography (MSOT) system (Fig. 3b), produced by iThera
Medical, guides the laser beam to illuminate a ring of light
around the animal being imaged, and then moves in the
third dimension to acquire volumetric images. 15 The Nexus
128 (Fig. 3c), produced by Endra, provides an alternative
tomographic photoacoustic system. All of these systems
consist of a tunable laser source providing near infrared
(NIR) light approximately between 680 to 970 nm. The
choice of a scanning or tomographic system depends greatly upon the application. The user must consider the achievable resolution, which is dependent upon the center frequency and bandwidth of the transducer, the beamforming
or reconstruction algorithms implemented, and also the
achievable sensitivity, which is influenced by the light fluence and distribution delivered within the tissue. An ultrasound scanning system will generally be most flexible,
accommodating a variety of animal types, and potentially
providing multiple transducer arrays optimized for differ-

ent scanning depths. A photoacoustic imaging system based
up on an ultrasound scanner platform provides additional
functional imaging techniques (such as ultrasound Doppler
mode) to provide anatomical and functional information.
In contrast, tomographic systems are capable of acquiring
volumetric data in a shorter period of time, and have less
noise in the form of photoacoustic speckle due to the spatial
distribution of the transducer ring. However, clinical applications of a photoacoustic tomography system will be limited, with a notable exception being the photoacoustic tomographic imaging of breast tissue. 16

The Walter Munk Award
Awarded in Recognition of Distinguished Research
in Oceanography Related to Sound and the Sea

C a ll f o r N o m in a t i o n s
The Walter Munk Award is granted jointly by
The Oceanography Society, the Oﬃce of Naval Research,
and the Oﬃce of the Oceanographer of the Navy.
Recipients are selected based on their:
t� 4JHOJmDBOU�PSJHJOBM�DPOUSJCVUJPOT�UP�UIF�VOEFSTUBOEJOH�PG�QIZTJcal ocean processes related to sound in the sea
t� 4JHOJmDBOU�PSJHJOBM�DPOUSJCVUJPOT�UP�UIF�BQQMJDBUJPO�PG�BDPVTUJD��
methods to that understanding
t� 0VUTUBOEJOH�TFSWJDF�UIBU�GPTUFST�SFTFBSDI�JO�PDFBO�TDJFODF�BOE�
instrumentation contributing to the above
For more information and nomination instructions, please visit:
www.tos.org/awards_honors/munk_award.html
Nomination deadline is March 31, 2013.

THE OCEA
CEANOGRAPHY
ANOGRAPHY SOC
OCIETY
IETY
The Oceanography Society, PP..O
O . Box 1931, Rockville, MD 20849-1931, USA
Telephone: 301/251-7708, Fax: 301/251-7709; E-mail: info@tos.org; Web site: www.tos.org

Photoacoustic Imaging for Medical Diagnostics

17

�Diagnostic
While optical
photoacoustic
absorbers naturally
imaging
found within the
In our studies,
body, such as
anatomical, funchemoglobin, lipids,
tional, and molecuand melanin, can
lar information was
be used to generate
acquired using a
photoacoustic
combination
of
images, the use of
ultrasound
and
nano-sized imagFig. 4. Transmission electron microscopy images of plasmonic metallic nanoparticles which have been used for
multiwavelength
ing contrast agents
in vivo photoacoustic imaging. (a) Gold nanospheres; (b) Silver nanoplates; (c) Gold nanorods coated with
photoacoustic
allows photoacoustic
silica. Scale bars = 100 nm.
imaging of in vivo
imaging to become
mice bearing cancerous tumors. All methods follow protocols
a truly “molecular” in vivo imaging method.17,18
approved by the Institutional Animal Care and Use
Photoacoustic contrast can be enhanced by the use of
Committee at the University of Texas at Austin. First, we
molecular dyes or chemically synthesized nanoparticles.
developed a small animal model of breast cancer which conInorganic nanoparticles are of particular interest, due to
sisted of two tumors established from human breast cancer
their flexibility with respect to shape, size, and surface
cell lines with differential cell biomarker expression. For this
chemistry. These characteristics can be optimized for
small animal model, we initiated tumors within the mammaenhanced delivery of the nanoparticles to the tissue of
ry fat pad using injections of BT-474 cancer cells, which overinterest, such as cancerous tumors.19 If the nanoparticle surexpress the cellular receptor HER2, and MDA-MB-231 cancer
face is modified by the addition of a targeting moiety, these
cells, which over-express αvβ3 integrin, present on the cell surcontrast agents become molecular imaging agents, since the
face of epithelial cells of neovasculature. Gold nanorods were
targeted nanoparticles should be preferentially retained
chosen as the molecular contrast agent since, in addition to
within the tissue region expressing the target. In addition,
being highly optically absorbing due to surface plasmon resometallic nanoparticles of gold or silver, several examples of
nance effects, their optical absorption spectra can be tuned by
which are shown in Fig. 4, have surface plasmon resonance,
changing their aspect ratio.23 By tuning nanorods to have difmeaning that the valence electrons of the atoms collectiveferent peak optical absorption wavelengths, it is possible to
ly oscillate at a characteristic frequency. When the incident
distinguish between multiple nanorod contrast agents
light is at the same frequency as the surface plasmon resothrough multiwavelength photoacoustic imaging.24 We coated
nance, that light is very efficiently absorbed and converted
the nanorods with amorphous silica, which improves the gold
into heat, making metallic nanoparticles excellent contrast
nanorod thermal stability25 and the photoacoustic signal genagents for photoacoustic imaging. Nanoparticles which are
eration efficiency.26 Silica-coated nanorods with two different
molecularly targeted can be customized for delivery to paraspect ratios were chemically modified to attach targeting
ticular tissues based on size, shape, and surface properties,
antibodies, allowing the nanoparticle to be preferentially
while the high optical absorption of metallic nanoparticles
uptaken by tumor cells over-expressing the targeted cellular
generates a strong photoacoustic signal and provides high
receptor.24 The contrast agents were injected into the bloodcontrast with the surrounding tissue. By using metallic
stream of a mouse growing the tumors. The injected contrast
nanoparticles, we can also tune their optical absorption
agents distributed through the circulatory system, and infilproperties to take advantage of the “tissue optical window”.
trated through the tissues of the mouse, including the cancerWithin this wavelength region, between approximately 600
ous tumors.
nm to 1300 nm, the native tissue optical absorption is relaThe tumor region of the mouse was imaged using a Vevo
tively low, and therefore light can penetrate deeper into tis2100 high frequency small animal ultrasound scanner
sue, allowing for acquisition of photoacoustic images at sig(VisualSonics Inc.), integrated with a SpectraPhysics
nificantly greater tissue depths. By imaging at wavelengths
QuantaRay Pro Nd:YAG nanosecond pulsed laser with a
which are not highly absorbed in tissues, the photoacoustic
GWU PremiScan optical parametric oscillator (OPO) to tune
effect can be used to generate high resolution molecular
the light wavelength. A fiber optic bundle was used to deliver
images in vivo at significant tissue depth. Questions remain
the laser light on either side of a linear transducer array. The
regarding the safety of metallic nanoparticles for use in the
system was used to deliver between 10-20 mJ/cm2 of light over
human body.20,21 Indeed, there is much that is still
a range of wavelengths from 680-930 nm. A 21-MHz ultraunknown about both their short-term and long-term toxsound transducer (MS250, VisualSonics Inc.) collected the
icity, but many groups are studying these effects,21 and
photoacoustic signals at each wavelength, followed by the
three clinical studies of gold nanoparticle-based methodtransmission of ultrasound and the receiving of the reflected
ologies for treatment of cancer are underway or have been
ultrasound by the same transducer, resulting in co-registered
completed.22 Additionally, photoacoustic imaging could
ultrasonic and photoacoustic images. A linear stepper motor
play a role in improving the understanding of the biodiswas used to translate the transducer and fiber bundle contribution and clearance mechanisms affecting the toxicity
struct, in steps of 150 µm, to acquire photoacoustic and ultraof nanoparticles.
18

Acoustics Today, October 2012

�Fig. 5. In vivo anatomical photoacoustic and ultrasound images. (a) 3D overlay of photoacoustic and ultrasound images of the upper leg/abdominal region. Blue box shows
the 2D imaging plane of (b-d). (b) Ultrasound image showing two hypoechoic tumors. (c) Photoacoustic image, acquired using a laser wavelength of 850 nm. (d) Overlay
of photoacoustic and ultrasound images. Scale bars = 2 mm.

sound images in the third dimension,
averaging four photoacoustic signals at
each step. Three-dimensional (3D)
ultrasound and photoacoustic images
were captured in a volume surrounding
the two tumors within the mammary
fat pad of the mouse.
The amplitude of the photoacoustic signal received is dependent
upon the wavelength of the laser light
used to illuminate the sample. This
dependence can be unmixed into the
individual absorption spectra of the
absorbers within the tissue—oxyhemoglobin, deoxyhemoglobin, nanoparticle 1 and nanoparticle 2. We used a linear least squared error spectral unmixing method where each voxel was
assumed to contain a combination of
the four optical absorbers.27 In this
method, the initial photoacoustic signal, located at a position within the
image, depends on the concentration of
the absorbers in the region, the laser
fluence, and the Grüneisen parameter.28
The optical absorption spectra of
hemoglobin were obtained from the literature29 and the nanoparticle spectra
were measured using UV-Vis spectroscopy (Synergy HT microplate reader, Biotek Instruments, Inc.). If the
spectral unmixing problem is overconstrained, which is achieved by
acquiring photoacoustic data at more

Fig. 6. In vivo functional imaging of blood oxygen saturation. (a) 3D overlay of percent blood oxygen saturation,
determined from spectral unmixing of the multiwavlength photoacoustic signal, and the ultrasound image.
Volume is 23 mm (wide) x 6 mm (tall) x 7 mm (scanned direction). (b) 2D slice of the percent blood oxygen saturation and ultrasound signal. Black arrow indicates a hypoxic region within a tumor. Scale bars = 2mm.

Photoacoustic Imaging for Medical Diagnostics

19

�wavelengths than the number of absorbers present in the tissue, then a minimum mean squared error estimate can be
obtained for the absorber concentrations. The estimated concentrations of deoxyhemoglobin, oxyhemoglobin, nanoparticle 1, and nanoparticle 2 are displayed using blue, red, green,
and violet colormaps, respectively. For spectral unmixing, the
data was averaged into voxels of size 500 µm 200 µm 300 µm.
The images of the optical absorbers were overlaid on co-registered ultrasound grayscale images to visualize the anatomy
in the region.
High resolution 3D anatomical images of the tumor
region were generated by processing the ultrasound signals
received by the integrated ultrasound and photoacoustic
imaging system (Fig. 5). In Fig. 5a, a 3D image of a single
wavelength photoacoustic image, overlaid on the ultrasound
image, clearly shows the anatomy within the imaged region
of the mouse, including the vasculature (in color, provided by
the photoacoustic image), and the layer of skin and the femur
within the leg (in greyscale, provided by the ultrasound
image). In our mouse model we can identify the tumor
regions by locating two hypoechoic regions under the skin, as
shown in the 2D ultrasound slice in Figure 5b. From the photoacoustic signal (Fig. 5c and 5d), it is clear that there are
light absorbers within the skin, light absorption from vasculature surrounding the tumors, and from the tumors themselves. While both ultrasound and photoacoustic images
indicate the presence of tumors, the anatomical images alone
do not provide sufficient information to diagnose malignancy, since the accuracy of ultrasound in the distinction of
benign and malignant tumors is insufficient.30 While the in
vivo ultrasound and single wavelength photoacoustic images
in Fig. 5 provide high resolution anatomical information, the
cellular composition of the tumor is unknown, and thus we
are unable, at this stage of imaging, to identify functional
characteristics or the cellular molecular expression, which
might aid in the identification of a benign versus cancerous
tumor.
Functional photoacoustic images, for example of the
blood oxygen saturation of the tumor, could provide additional criteria to assess tumor function. We acquired functional information by detecting photoacoustic signals at multiple laser wavelengths and spectrally unmixing the signals as
described above. For functional imaging of the animal model

described above, we acquired photoacoustic signals generated by laser light between 680-850 nm. As shown in Figure 6,
we can observe the oxygen saturation of the blood within the
“normal” tissue and within the tumor regions. The estimated
concentrations of deoxyhemoglobin and oxyhemoglobin are
shown using a color scale ranging from blue (0% oxygen saturation) to red (100% oxygen saturation). The 3D image
shown in Figure 6a indicates distinction of venuous flow
from arterial flow within vasculature of the imaged tissue.
While the study of vasculature has relevance to some niches
of medical diagnostics, more significantly, we can use the
functional information provided by the multiwavelength
photoacoustic imaging to study the tumor blood oxygen saturation. Hypoxic malignant tumors have a worse prognosis,
making the blood oxygen saturation useful for the assessment of therapy and therapy response.31 As shown in Fig. 6b,
there is a hypoxic region within the core of the imaged tumor.
This lower oxygen saturation is likely due to the high metabolic activity of the cells located within that region, leading to
insufficient oxygen delivery within the tumor. Functional
photoacoustic imaging of the blood oxygen saturation could
be used to study the response of the tumor to therapeutic
treatment, non-invasively, in real-time, and over long time
periods of tumor growth.
Finally, we can further process the photoacoustic
images to view the signal which correlates to the optical
absorption spectra of the injected contrast agents. In the
studies shown here, we have used silica-coated gold
nanorods, but it important to note that a large variety of
contrast agents can be successfully used for molecular photoacoustic imaging;32 in vivo photoacoustic imaging with
enhanced contrast has been demonstrated with the FDAapproved dye methylene blue, 33 with gold nanospheres,27 or
with silver nanoplates.34 As shown in Fig. 7, within our
mouse model, regions of nanoparticle accumulation correspond to the tumor regions identified with the ultrasound
imaging and the functional photoacoustic imaging of the
blood oxygen saturation. Over time, there is an increase in
the signal attributed to the nanoparticle contrast agents
within the tumor region (Fig. 7b, c). The accumulation of
nanoparticles could be due to two effects. It is known that
tumors have “leaky” vasculature, enabling the increased
delivery of nano-sized particles through the enhanced per-

Fig. 7. In vivo molecular imaging of contrast agent accumulation within a targeted tumor. The multiwavelength photoacoustic signal was unmixed into two components corresponding to two different contrast agents, nanoparticle 1 (NP1) and nanoparticle 2 (NP2). (a) 2D overlay of ultrasound image, distribution of NP1 and NP2 before the
injection of the contrast agent, showing minimal background photoacoustic signal. Accumulation of NP1 and NP2 within the tumor is shown (b) 8 hours and (c) 24 hours
after intravenous injection. Scale bars = 1 mm.
20

Acoustics Today, October 2012

�meability and retention effect. Additionally, the injected
nanoparticles were bioconjugated to antibodies specific for
cell receptors over-expressed on cell types used to initiate the
tumors, thus it is likely that the active targeting improves the
retention of the specific nanoparticles within the tumor
region. This example demonstrates how the use of nanoparticles can provide molecular information about the cellular
expression of the tumor. In this way, photoacoustics combines the benefits of high-contrast optical resolution of targetable light-interacting probes, with the imaging depth
capabilities of ultrasound.

Conclusions
The strength of photoacoustic imaging is in its ability to
image functional and molecular changes, at significant tissue
depth, in living animals. Researchers have just begun to
exploit photoacoustic imaging techniques to enable new discoveries of the functional and molecular characteristics of
cancer, cardiovascular disease, and neurological diseases. We
envision photoacoustic imaging becoming a critical tool in
medical diagnostics and image-guided therapeutics in the
future. While most photoacoustic functional imaging applications thus far have used contrast sources which are naturally present, it is also possible to introduce biochemically
triggered contrast agents for functional imaging. For example, many dyes exist which change their optical absorption
spectra based on pH, or in the presence of an enzyme. By
adding an activatable contrast agent, we can use the change
in the multiwavelength photoacoustic signal intensity to provide quantitative information about the biochemical environment within tissues, and monitor changes in this environment.
While this article focuses on imaging, it is also of note
that a natural synergy exists between photoacoustic imaging
and therapy. For example, thermal therapy can be achieved
by using a continuous light source to heat the optical
absorbers used for photoacoustic contrast, to a temperature
which can lead to the destruction of the cells and surrounding tissue.35 Additionally, multimodal photoacoustic contrast
agents can be designed to provide laser-activated delivery of
therapeutic molecules, such as by using a temperatureresponsive polymer coating,36 or by using the heat to release
covalently-linked therapeutics.37
Photoacoustic imaging is not without limitations. Like
ultrasound, the resolution will be physically limited by the
inverse relationship between the imaging depth and the frequency of the ultrasound—as the frequency increases, resolution also increases, however the signal attenuation is
greater at higher frequencies, leading to limitations in imaging depth. Sensitivity is impacted by the scattering of light
within tissue, however new techniques to maximize the signal to noise, including improved contrast agents, and varying
the laser light characteristics, can help to minimize background signal. Other limitations include the time required to
scan—achieving high lateral resolution is dependent upon a
narrow beam, which means that the receiving transducer (in
scanning systems) or object being imaged (in tomographic
systems) must be scanned in a third dimension to widen the
field of view. This time limitation does limit the temporal res-

olution of the functional and molecular information which
can be obtained to the timescale of minutes. Currently, only
preclinical photoacoustic imaging systems are available commercially, but the additional functional and molecular information available through this imaging modality will mean its
increasing use in preclinical studies, providing the needed
research background necessary for clinical adaptations.AT

Acknowledgements
The authors acknowledge support from the National
Institutes of Health (NIH) under grants F32CA159913 (C.L.
Bayer), and F31CA168168 (G.P. Luke). We thank Juili Kevlar
for providing the silica-coated gold nanorod TEM images,
and Dr. Kimberly Homan for providing the silver plate TEM
images. We also thank Shailja Tewari of VisualSonics,
Christian Wiest of iThera Medical, and Richard Moss of
Endra Life Sciences for providing the pictures compiled in
Fig. 3.
References
1

2
3

A. G. Bell, “On the production and reproduction of sound by
light,” Am. J. Sci. 20, 305-324 (1880).
R. A. Kruger “Photoacoustic ultrasound,” Med. Phys. 21, 127131 (1994).
A. A. Oraevsky, S. L. Jacques, R. O. Esenaliev, and F. K. Tittel
“Time-resolved optoacoustic imaging in layered biological tissues,” OSA Proc.Advances in Optical Imaging and Photon

TUNE INTO ZERO’s
SOUND SOLUTIONS
ZERO is a world-wide leader in high-performance acoustical control for
doors, windows and walls. Nobody does sound control better — we use
advanced technology and testing to master the challenges of creating
an effective barrier and preventing gaps in that barrier for the life of the
assembly. Our systems are rated for use in sound studios and recording
facilities, music halls, etc — up to 55 STC. Let us help you close the
door on noise — contact us for a copy of our 20 page Sound Control
brochure, and our 72 page Product Catalog, or visit our website.

1-800-635-5335 / 718-585-3230 FAX 718-292-2243
zero@zerointernational.com www.zerointernational.com

Photoacoustic Imaging for Medical Diagnostics

21

�4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19
20

22

Migration 21, 161-165 (1994).
X. Wang, Y. Pang, G. Ku, X. Xie, G. Stoica, and L. V. Wang
“Noninvasive laser-induced photoacoustic tomography for
structural and functional in vivo imaging of the brain,” Nature
Biotechnol. 21, 803-806 (2003).
S. Mallidi, G. P. Luke, and S. Emelianov “Photoacoustic imaging
in cancer detection, diagnosis, and treatment guidance,” Trends
in Biotechnol. 29, 213-221 (2011).
J. Laufer, P. Johnson, E. Zhang, B. Treeby, B. Cox, B. Pedley, and
P. Beard “In vivo preclinical photoacoustic imaging of tumor
vasculature development and therapy,” J. Biomed. Optics 17,
056016-1 (2012).
E. W. Stein, K. Maslov, and L. V. Wang “Noninvasive, in vivo
imaging of blood-oxygenation dynamics within the mouse brain
using photoacoustic microscopy, ” J. Biomed. Optics 14, 020502020502 (2009).
J. Laufer, E. Zhang, G. Raivich, and P. Beard “Three-dimensional noninvasive imaging of the vasculature in the mouse brain
using a high resolution photoacoustic scanner,” Appl.Optics 48,
D299-306 (2009).
V. Tsytsarev, K. I. Maslov, J. Yao, A. R. Parameswar, A. V.
Demchenko, and L. V. Wang “In vivo imaging of epileptic activity using 2-nbdg, a fluorescent deoxyglucose analog,” J.
Neurosci. Methods 203, 136-140 (2012).
A. Taruttis, E. Herzog, D. Razansky, and V. Ntziachristos “Realtime imaging of cardiovascular dynamics and circulating gold
nanorods with multispectral optoacoustic tomography,” Optics
Express 18, 19592-19602 (2010).
X. Cai, B. S. Paratala, S. Hu, B. Sitharaman, and L. V. Wang
“Multiscale photoacoustic microscopy of single-walled carbon
nanotube-incorporated tissue engineering scaffolds,” Tissue
Engineering Part C Methods 18, 310-317 (2012).
S. Y. Nam, L. M. Ricles, L. J. Suggs, and S. Y. Emelianov “In vivo
ultrasound and photoacoustic monitoring of mesenchymal stem
cells labeled with gold nanotracers,” PLoS ONE 7, e37267
(2012).
D. Piras, W. Xia, W. Steenbergen, T. van Leeuwen, and S. G.
Manohar “Imaging breast lesions using the twente photoacoustic mammoscope: Ongoing clinical experience,” Proc. SPIE
8223, 82231-82230C (2012).
G. P. Luke, D. Yeager, and S. Y. Emelianov “Biomedical applications of photoacoustic imaging with exogenous contrast agents,”
Ann. Biomed. Eng. 40, 422-437 (2012).
D. Razansky, A. Buehler, and V. Ntziachristos “Volumetric realtime multispectral optoacoustic tomography of biomarkers,”
Nature Protocols 6, 1121-1129 (2011).
R. A. Kruger, R. B. Lam, D. R. Reinecke, S. P. Del Rio, and R. P.
Doyle “Photoacoustic angiography of the breast,” Med. Phys. 37,
6096-6100 (2010).
A. Agarwal, S. W. Huang, M. O’Donnell, K. C. Day, M. Day, N.
Kotov, and S. Ashkenazi “Targeted gold nanorod contrast agent
for prostate cancer detection by photoacoustic imaging,” J. Appl.
Phys. 102 (2007).
P.-C. Li, C.-R. C. Wang, D.-B. Shieh, C.-W. Wei, C.-K. Liao, C.
Poe, S. Jhan, A.-A. Ding, and Y.-N. Wu “In vivo photoacoustic
molecular imaging with simultaneous multiple selective targeting using antibody-conjugated gold nanorods,” Optics Express
16, 18605-18615 (2008).
R. K. Jain, and T. Stylianopoulos “Delivering nanomedicine to
solid tumors,” Nature Reviews Clinical Oncol. 7, 653-664 (2010).
R. Goel, N. Shah, R. Visaria, G. F. Paciotti, and J. C. Bischof

Acoustics Today, October 2012

21

22

23

24

25

26

27

28

29
30

31
32

33

34

35

36

37

“Biodistribution of tnf-alpha-coated gold nanoparticles in an in
vivo model system,” Nanomedicine 4, 401-410 (2009).
N. Khlebtsov, and L. Dykman “Biodistribution and toxicity of
engineered gold nanoparticles: A review of in vitro and in vivo
studies,” Chem. Soc. Rev. 40, 1647-1671 (2011).
Clinicaltrials.gov [Internet] Bethesda: U.S. National Institutes of
Health. 2000- [cited 2012 Sept 1]. Available from:
http://www.clinicaltrials.gov/.
P. K. Jain, K. S. Lee, I. H. El-Sayed, and M. A. El-Sayed
“Calculated absorption and scattering properties of gold
nanoparticles of different size, shape, and composition:
Applications in biological imaging and biomedicine,” J. Phys.
Chem. B 110, 7238-7248 (2006).
C. L. Bayer, Y. S. Chen, S. Kim, S. Mallidi, K. Sokolov, and S.
Emelianov “Multiplex photoacoustic molecular imaging using
targeted silica-coated gold nanorods,” Biomed. Optics Express 2,
1828-1835 (2011).
Y.-S. Chen, W. Frey, S. Kim, K. Homan, P. Kruizinga, K. Sokolov,
and S. Emelianov “Enhanced thermal stability of silica-coated
gold nanorods for photoacoustic imaging and image-guided
therapy,” Optics Express 18, 8867-8878 (2010).
Y. S. Chen, W. Frey, S. Kim, P. Kruizinga, K. Homan, and S.
Emelianov “Silica-coated gold nanorods as photoacoustic signal
nanoamplifiers,” Nano Lett. 11, 348-354 (2011).
S. Kim, Y.-S. Chen, G. P. Luke, and S. Y. Emelianov "In vivo
three-dimensional spectroscopic photoacoustic imaging for
monitoring nanoparticle delivery,” Biomed. Optics Express 2,
2540-2550 (2011).
S. Kim, Y.-S. Chen, G. P. Luke, and S. Y. Emelianov “In vivo
three-dimensional spectroscopic photoacoustic imaging for
monitoring nanoparticle delivery,” Biomed. Optics Express 2,
2540-2550 (2011).
S. Prahl “Optical absorption of hemoglobin,” (Oregon Medical
Laser Center) (1999).
C. Sehgal, S. Weinstein, P. Arger, and E. Conant “A review of
breast ultrasound,” J. Mammary Gland Biology and Neoplasia
11, 113-123 (2006).
A. L. Harris “Hypoxia--a key regulatory factor in tumour
growth,” Nature Reviews Cancer 2, 38-47 (2002).
G. P. Luke, D. Yeager, and S. Y. Emelianov “Biomedical applications of photoacoustic imaging with exogenous contrast agents,”
Ann. Biomed. Eng. 40, 422-437 (2012).
K. H. Song, E. W. Stein, J. A. Margenthaler, and L. V. Wang
“Noninvasive photoacoustic identification of sentinel lymph
nodes containing methylene blue in vivo in a rat model,” J.
Biomed. Optics 13, 054033 (2008).
K. A. Homan, M. Souza, R. Truby, G. P. Luke, C. Green, E. Vreeland,
and S. Emelianov “Silver nanoplate contrast agents for in vivo
molecular photoacoustic imaging,” ACS Nano 6, 641-650 (2012).
J.-W. Kim, E. I. Galanzha, E. V. Shashkov, H.-M. Moon, and V. P.
Zharov “Golden carbon nanotubes as multimodal photoacoustic
and photothermal high-contrast molecular agents,” Nature
Nanotechnology 4, 688-694 (2009).
D. E. Owens, J. K. Eby, Y. Jian, and N. A. Peppas “Temperatureresponsive polymer–gold nanocomposites as intelligent therapeutic systems,” J. Biomed. Mat. Res. Part A 83A, 692-695
(2007).
W. F. Zandberg, A. B. S. Bakhtiari, Z. Erno, D. Hsiao, B. D. Gates,
T. Claydon, and N. R. Branda “Photothermal release of small
molecules from gold nanoparticles in live cells,” Nanomedicine
8, 908-915 (2012).

�Carolyn L. Bayer is a Ruth L. Kirschstein National Research
Service Award (NRSA) Postdoctoral Fellow at the University
of Texas at Austin. She completed a B.S. in Electrical
Engineering at Case Western Reserve University, and a Ph.D
in Biomedical Engineering at the University of Texas at
Austin. Her postdoctoral research uses multiwavelength
photoacoustic imaging, in combination with biomolecularlytargeted nanoparticle contrast agents, to monitor the development of distinctive molecular signatures involved in tumor
growth and response to treatment in vivo.

Geoffrey Luke is a Ruth L. Kirschstein National Research
Service Award (NRSA) Predoctoral Fellow in the
Department of Electrical Engineering at The University of
Texas at Austin. He received a B.S. in Computer Engineering
and Mathematics and a M.S. in Electrical Engineering from
the University of Wyoming, where he developed a sensor
based on the visual system of the common housefly. His current research is focused on early cancer detection and characterization using molecular photoacoustic imaging.

Stanislav Emelianov received B.S. and M.S. degrees in physics
and acoustics in 1986 and 1989, respectively, and a Ph.D.
degree in physics in 1993 from Moscow State University,
Russia. In 2002, Dr. Emelianov moved to The University of
Texas at Austin and formed the Ultrasound Imaging and
Therapeutics Research Laboratory. Dr. Emelianov’s research
interests are in the areas of medical imaging for therapeutics
and diagnostic applications, ultrasound microscopy, elasticity imaging, photoacoustical imaging, cellular/molecular
imaging, and functional imaging. Dr. Emelianov has published over 100 archival publications and over 12 book chapters. Throughout his career he has mentored and served on
dissertation committees of more than 43 graduate students.
Finally, Dr. Emelianov is an American Institute for Medical
and Biological Engineering (AIMBE) fellow and is currently
Vice President of the Institute of Electrical and Electronics
Engineers (IEEE) Ultrasonics, Ferroelectrics and Frequency
Control Society.

Photoacoustic Imaging for Medical Diagnostics

23

�O-splines para analizar señales
de oscilaciones de potencia
José Antonio De la O Serna

Universidad Autónoma de Nuevo León
Facultad de Ingeniería Mecánica y Eléctrica
jose.delaosr.uanl.edu.mx
RESUMEN
Se presenta una nueva familia de splines y sus derivadas, las cuales provienen
de los diferenciadores pasabajas de la Transformada Discreta Taylor-Fourier
(DTFT). Se llaman O-splines porque sus segmentos están espaciados en tramos de
un ciclo de la frecuencia fundamental. Con ellas se analizan señales oscilatorias
de potencia. Para ilustrar su aplicación y su progresiva exactitud se aplican
para estimar fasores de voltajes, y para separar modos electromecánicos de
oscilación en un sistema de potencia real. Con ellas se disminuye la complejidad
computacional de la DTFT, ya que se aplica solamente un subconjunto de filtros.
Los parámetros estimados ofrecen información dinámica mucho más rica que los
métodos tradicionales. En particular, brindan una representación de estados para
cada componente oscilatoria, y detección de eventos modulados en frecuencia. Su
rendimiento en estimación se evalúa con un nuevo error llamado Error Fasorial
Total (Total Phasor Error). Se concluye que esta técnica multiresolución ofrece
una serie de soluciones de gradual exactitud para la estimación fasorial y la
separación de modos de oscilación. Este nuevo marco matemático fusiona el
área de medición fasorial con la de análisis de modos de oscilación en sistemas
eléctricos de potencia que tradicionalmente han estado separadas en ingeniería
eléctrica.
PALABRAS CLAVE
Transformada Discreta Taylor Fourier, fasor dinámico, modos
electromecánicos, detección de envolvente compleja, bancos de filtros, análisis
multiresolución, armónicas oscilatorias, O-splines, espacio de fase, oscilaciones
de potencia, estimación de sincrofasores, separación tiempo-frecuencia, error
fasorial total.
ABSTRACT
A new family of splines and their derivatives is presented, which come from
the low-pass differentiators of the Discrete Taylor-Fourier Transform (DTFT).
They are called O-splines because their segments are spaced in steps of a
cycle from the fundamental frequency. With them oscillatory power signals are
analyzed. To illustrate their application and their progressive accuracy, they
are applied to estimate voltage phasors, and to separate electromechanical
modes of oscillation in a real power system. With them, the computational
complexity of the DTFT is reduced, since only a subset of filters is applied.
The estimated parameters offer much richer dynamic information than
traditional methods. In particular, they provide a representation of states for

42

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

each oscillatory component, and detection of frequency modulated events. Its
estimation performance is evaluated with a new error called Total Phasor
Error. It is concluded that this multiresolution technique offers a series of
solutions of gradual accuracy for the phasor estimation and the separation of
oscillation modes. This new mathematical framework merges the area of ​​phasor
measurement with that of analysis of modes of oscillation in electrical power
systems that have traditionally been separated in electrical engineering.
KEYWORDS
Discrete Taylor Fourier Transform, dynamic phasor, electromechanical modes,
complex envelope detection, filter banks, multiresolution analysis, oscillatory
harmonics, O-splines, phase space, power oscillations, synchrophasor estimation,
time-frequency separation, total phasor error.
INTRODUCCIÓN
La medición de señales oscilatorias de sistemas eléctricos de potencia
es considerada en la literatura como dos problemas independientes. Por una
parte, hay muchos estudios para implementar mejores algoritmos para medir
sincrofasores de señales de voltaje y de corriente bajo oscilaciones para las
unidades de medición fasorial (PMUs) instaladas en las redes inteligentes de
área amplia. Por la otra, existe una abundante literatura dedicada a mejorar el
análisis de modos electromecánicos de oscilaciones de potencia. Este artículo
propone los O-splines de la Transformada Discreta Taylor Fourier para resolver
estos dos importantes problemas.
Ambos problemas tienen en común componentes de señal con energía espectral
densa alrededor de ciertas frecuencias: de las frecuencias armónicas en el primer
caso, y junto a las frecuencias de los modos de oscilación en el segundo. El
problema básico de la transformada de Fourier (DFT) al tratar con componentes
espectrales densas es que distorsiona tanto la amplitud como la fase. 1 La DFT
trabaja con exactitud solo cuando las señales tienen componentes con amplitud,
fase y frecuencia constantes. La transformada Taylor Fourier (DTFT) resuelve esta
limitación sustituyendo cada coeficiente de Fourier constante por un polinomio
de Taylor de orden K durante la duración temporal de la ventana de observación.
Esto le permite capturar la envolvente compleja de cada componente.
Subespacios más amplios se generan incluyendo términos de Taylor de más
alto orden en cada componente armónica de la base de Fourier. 2 Dado que los
polinomios de Taylor de más alto orden incluyen los de orden inferior, cada
término de Taylor incluido en el modelo de señal hace que el subespacio crezca
gradualmente desde el anterior. Por tanto, las extensiones de polinomios de
Taylor generan una escalera de espacios con elementos que se aproximan cada
vez más a la señal pasabanda ideal. Inician con el más burdo, definido por los
coeficientes complejos de la DFT, en el cual residen las señales periódicas. Al
agregar más y más términos de Taylor al modelo de señal, se generan subespacios
más vastos, conteniendo los anteriores. Entonces, los subespacios DTFT ofrecen
mejores aproximaciones a las señales oscilatorias, y por tanto brindan parámetros
dinámicos con errores cada vez más pequeños. Consecuentemente, los estimados
obtenidos con polinomios de grados superiores son siempre más precisos y exactos
en señales oscilatorias que los obtenidos con grados inferiores.
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

43

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

En este trabajo (cuya versión en inglés se encuentra en 3) se comparan los
parámetros estimados con polinomios de Taylor de primer y tercer orden.
Además, se demuestra que las respuestas impulsionales de los filtros DTFT
son modulaciones a las frecuencias armónicas de las O-splines. Por tanto, nos
concentramos en los diferenciadores pasabajas. Los O-splines son funciones
definidas por segmentos polinomiales. En nuestro caso, cada ciclo es definido
por un polinomio distinto.
En el lado espectral, la extensión de Taylor ensancha y aplana el lóbulo
principal de los filtros DTFT. Como resultado de esta relajación espectral, los
filtros de la DTFT son más adecuados para medir armónicas oscilatorias, ya que
no las distorsionan ni en amplitud ni en fase. En cuanto a la descomposición
de la señal, la DTFT está dotada de un banco de filtros con ganancias de
diferenciador ideal en su banda de paso, y con bandas de paro con ganancia
nula en el resto de las armónicas. Por tanto, en cada frecuencia armónica, los
filtros actúan como diferenciadores ideales, con rechazo perfecto del resto de
las armónicas.
Con respecto a la aplicación de estimación de sincrofasores, vale la pena
mencionar que el estándar de sincrofasores 4 fue escrito bajo la fuerte influencia
de estimador tradicional DFT de un ciclo. 5 Ahora el énfasis del estándar
está puesto en el efecto del ruido en las estimaciones. 6 Pero se defiende
persistentemente el filtro de Fourier a pesar de sus conocidas limitaciones
en condiciones oscilatorias (la infiltración de la imagen de la frecuencia
fundamental, y la pérdida debida a su ganancia en forma de concha). 7, 8 Por
estas razones, después de reconocer la buena regulación en estado estable del
estándar de sincrofasores del IEEE, el Consejo de Coordinación de Electricidad
del Oeste (Western Electricity Coordinating Council (WECC)) 9 propuso
mejorar los requisitos de rendimiento dinámico de los filtros usados en PMUs,
a fin de garantizar mejores respuestas ante condiciones dinámicas, tales como
vaivenes de potencia o armónicas cambiantes. Y propuso un filtro complejo
de pasabanda adaptiva derivado de la teoría de bancos de filtros modulados
exponencialmente, con respuestas impulsionales de 4 y 7 ciclos, y variaciones
frecuenciales en el rango entre 40 a 80 Hz. Aquí se propone la serie de respuestas
impulsionales de los diferenciadores pasabanda DTFT para observar la dinámica
de señales oscilatorias. Las soluciones ofrecidas pueden graduarse para mejorar
la precisión y exactitud de los estimados, empezando con el filtro más burdo
(DFT), y terminando con mucho mejores representaciones óptimas para las
aplicaciones de protecciones (clase P) y de mediciones (clase M).
Por otra parte, la identificación de modos electromecánicos en oscilaciones
de potencia ha sido estudiada por muchos investigadores a través de las
siguientes aproximaciones: 10 análisis lineal de oscilaciones atenuadas
ringdown, 11, 12 análisis de modos, 13 y análisis no lineal. 14, 15 Estos métodos
(Prony, Yule Walker, and Hilbert Wang) consideran los modos de oscilación
como componentes de banda ancha localizados en cualquier parte del espectro,
mientras que la DTFT 16 particiona la frecuencia en un conjunto de intervalos
disjuntos desde los cuales la envolvente compleja de cada modo de oscilación
es observada a través de una descomposición de Taylor. Ofrece separación
tiempo-frecuencia en modos de frecuencia fluctuante, y una parametrización en

44

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

espacio de fase para las dinámicas de cada modo. Por supuesto, la frecuencia
central de los filtros DTFT debe sintonizarse con la frecuencia media central
de cada modo. 17 El ejemplo analizado en la sección de resultados ilustra la
nueva parametrización ofrecida por el análisis DTFT.
En este trabajo nos proponemos desarrollar un marco teórico que mejore la
estimación de sincrofasores en corrientes y voltajes, así como la la separación de
modos de oscilación en oscilaciones de potencia, motivados por la hipótesis de
multiresolución, según la cuál a los O-splines de más alto grado les corresponde
un error de aproximación mucho más pequeño, y en consecuencia estimaciones
paramétricas más completas y de mejor calidad.
En lo que sigue, el modelo de señal en subespacios Taylor Fourier se
presenta en la sección de metodología, con las respuestas impulsionales de los
filtros, y sus respuestas en frecuencia. Esto se hace para los diferenciadores
pasabanda de primer y tercer orden. En la sección de resultados se muestran
los fasores dinámicos de la DTFT estimados punto a punto con polinomios de
Taylor de primer y tercer orden y obtenidos de las señales de voltaje durante
una oscilación. Las estimaciones de amplitud, fase y frecuencia se ilustran para
mostrar cómo mejora la exactitud de las estimaciones. Finalmente, en la sección
de resultados, la DTFT es usada para separar los modos electromecánicos de
la oscilación de potencia. El análisis ilustra los estimados de amplitud y fase
de los primeros dos modos, junto con sus primeras derivadas. Concluye que
ambas aplicaciones de los O-splines enriquecen la representación paramétrica
de estos eventos dinámicamente complejos.
Metodología Utilizada
Se utiliza el método conocido como multiresolución, que consiste en definir
una escalera de subsepacios 18 para aproximar con más y más precisión las
señales analizadas. En nuestro caso los subespacios en cada frecuencia armónica
son graduados simplemente por el orden del polinomio de Taylor utilizado en
la DTFT. En esta sección se desarrolla esta idea.
La expansión del fasor estático al dinámico y sus derivadas se presentó
originalmente en 19. Esto condujo a la extensión del subespacio de Fourier a los
de Taylor Fourier presentados en 20. Esta puede ser aquí brevemente introducida
iniciando desde el tradicional modelo de señal de Fourier de orden cero:

donde
es la matriz de Fourier WN de N × N elementos, y contiene los
coeficientes de Fourier de .
Los elementos de WN son
, para n, k=0, 1, … , N-1, donde N
es el número de muestras por ciclo fundamental.
Se extiende el subespacio anterior incluyendo el primer término de Taylor.
El modelo de señal para esta primera extensión es entonces como muestra la
ecuación 2, en donde las matrices diagonales I y T contienen las muestras de
los términos de Taylor de cero y primer orden, respectivamente, tomados en
un intervalo centrado de dos ciclos. Y el subvector
N contiene las derivadas
de los primeros coeficientes Taylor Fourier en .
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

45

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Las siguientes extensiones se obtienen incluyendo más y más términos de
Taylor. El modelo de señal para la K-ésima extensión es como sigue:

donde la matriz
de (K+1)N × (K+1)N contiene los vectores de la base del
subespacio extendido, el subvector ξ N contiene los coeficientes Taylor Fourier de
K ésimo grado, y los subvectores ξ ( k ) N , k=1, … K sus progresivas derivadas.
Note que la extensión conlleva una prolongación cíclica del modelo de señal, de
C=1 a C=K+1 ciclos.
Debido a la oblicuidad introducida por los términos de Taylor, las bases
extendidas ya no son ortogonales, y por tanto, para K ≥ 1 , se requiere un
par de bases biortogonales para la proyección ortogonal: 21 una base para la
antitransformada en (3) y su dual para la transformada:

donde

es la matriz dual de

tal que
En 22 la matriz

dada por:

en (3) es factorizada como sigue:

en la cual las submatrices cuadradas Ti, i= 1, 2, … , C son las submatrices
diagonales descendientes de N × N elementos, extraídas de la matriz diagonal
T en (3). Note que
contiene la i-ésima pieza cíclica del k-ésimo término
de Taylor. En esta factorización, el operador Taylor Fourier
es claramente
separado en dos matrices:
del operador de Fourier y
del de Taylor.
Esta factorización fue propuesta en 22 para reducir los cálculos de , ya que
para la forma factorizada se tiene:

46

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

En este artículo, se propone la formulación de la DTFT en (7) como un método
de diseño de filtros pasabajas (diferenciadores pasabajas máximamente lisos) en
. Note que preserva la estructura de (6), puesto que los vectores de son
combinaciones lineales de los vectores en . En consecuencia, los vectores en
son simples modulaciones armónicas de las subdiagonales verticales de . En
otras palabras, esta factorización demuestra que el subconjunto de vectores banda
base en constituyen las envolventes de los correspondientes subconjuntos de
vectores en las frecuencias armónicas de la DTFT.
Esta contribución es importante para aplicaciones donde la energía está
presente en un pequeño número de frecuencias. Este es el caso de señales de
sistemas de potencia, ya que la aplicación de sincrofasores solamente requiere
los filtros pasabanda en la frecuencia fundamental, ya que tienen buen rechazo
en las frecuencias armónicas; y la de oscilaciones de potencia solo requiere
filtros en cada modo. En estas aplicaciones, la DTFT se implementa con una gran
reducción de complejidad computacional, ya que se reduce a la aplicación de un
pequeño numero de filtros de respuesta impulsional finita (FIR). Si se requiere
estimar hasta la segunda derivada, se requieren 3 filtros FIR de longitud (K+1) N
por frecuencia observada.
Con respecto a la sensibilidad del ruido de los filtros DTFT, se puede afirmar
16, 19, 20
que para señales con tasa de señal a ruido (SNR) arriba de 60 dB, el error
medio cuadrático de los parámetros estimados es despreciable.
Error de aproximación
La mejor señal aproximada a través de la descomposición DTFT se obtiene
a través de la matriz de proyección
, pues se tiene:

El teorema de Pitágoras se cumple para el error de aproximación
con

y normalizando con respecto a la energía de la señal,

El error cuadrático medio anterior considera el error de la proyección sobre
el subespacio total considerado, es decir el subespacio generado por todos los
vectores de la base en .
Es también posible medir el error de aproximación de la proyección en el
subespacio generado solamente por los vectores de la base asociados con la
frecuencia fundamental, que generan el subespacio fundamental. Esto es posible
tomando la submatriz
que contiene tales vectores, y los correspondientes
estimados
Esta medida será llamada Error Fasorial Total (TPE, por sus siglas
en Inglés), ya que mide la energía faltante a la señal aproximada del subespacio
fundamental. Esto, a su vez, corresponde a la Distorsión Total (TD) asociada a
la componente fundamental.
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

47

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Entonces se tiene:

Para una señal dada x , el mejor estimador fasorial es entonces el que minimice
el TPE. Como puede verse, la definición del TPE es la más general de las
distorsiones, pues toma en cuenta cualquier tipo de energía espectral presente en
la señal: subarmónicas, interarmónicas, y cualquier tipo de ruido. Para señales
periódicas, el TPE se reduce a la distorsión armónica total (THD), 23 y para
sinusoidales de estado estable el TPE se reduce al error vectorial total (TVE)
del estándar de sincrofasores. 4 Para las señales de prueba del estándar, el TPE
es la mejor medida de error, y no se correlaciona con el TVE. Una de las fuertes
limitaciones del TVE es que solo se puede obtener cuando el fasor dinámico de
la señal de prueba es conocido. El TPE se calcula con los datos de la señal dada
y la aproximada, y puede usarse para comparar diferentes algoritmos, sin que el
fasor dinámico subyacente de la señal sea conocido, como en el caso del TVE.
Además, el TPE tiene otras dos ventajas: depende del conjunto total de parámetros
estimados
y puede calcularse para intervalos de duración más cortos que el
intervalo usado en la estimación.
Respuesta impulsional y de frecuencia de los filtros FIR
Cuando K aumenta, los modelos de señal DTFT ofrecen una serie de
subespacios de aproximación V K , que forman una escalera de espacios, 18 con
un orden anidado:
, iniciando con el subespacio central
de la DFT, y progresando gradualmente como
, donde
W K-1 es el complemento ortogonal de
en . Entonces, iniciando con la
aproximación más burda, ellos ofrecen gradualmente aproximaciones de más alta
resolución. La principal diferencia entre la DTFT y el análisis multiresolución
de onduletas, es que los O-splines separan el espectro en bandas uniformes,
centradas en las frecuencias armónicas, mientras que las onduletas las separan
en bandas diádicas.
Como las respuestas impulsionales de los filtros DTFT en cada frecuencia
armónica son simples versiones moduladas de las de la banda base, concentramos
nuestra atención en esta banda, para luego entender la operación de los filtros
pasabanda.
La gráfica superior de la figura 1 ilustra los O-splines para diferentes grados
de Taylor K=0, 1 , … , 11. Éstas fueron calculadas con N=20 muestras por ciclo.
Puede demostrarse de 7 que forman una nueva familia de splines con C=K+1
ciclos. Las primeras dos corresponden a los splines B (B-splines) de cero y primer
orden, 24 pero luego difieren de éstas cuando K ≥ 2 , ya que las O convergen
al Seno Cardenal (Cardinal Sine), y no a la Gausiana como las B, como puede
corroborarse con la curva con K=11 . Inician con la ventana rectangular del filtro
Fourier de un ciclo, luego la triangular de dos ciclos, como el ejemplo de filtro
clase P del estándar de sincrofasores, 4 y entonces sus formas evolucionan hasta
la función Seno Cardenal, cuando K → ∞ . De hecho, el quinto filtro de 6 ciclos
es muy similar al filtro clase M del estándar 4.

48

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Fig. 1. O-splines (gráfica superior) y respuestas frecuenciales (gráfica inferior) de los
filtros DTFT pasabajas, K = 0, 1, … ,5 , y 11.

Por otro lado, la gráfica inferior de la figura 1 ilustra las respuestas en
frecuencia de los O-splines. Como se puede ver, la secuencia inicia con la
función Seno Cardenal, correspondiente a la ventana rectangular, seguida por su
cuadrado que corresponde a la ventana triangular. Después de éstas las respuestas
en frecuencia empiezan a tener pasabanda y bandas de paro cada vez más planas.
Esta propiedad es muy importante para el rechazo de armónicas. En la medida que
el grado de Taylor K aumenta, los O-splines tienden a la de un filtro pasabajas
ideal de forma perfectamente rectangular. Note que estos filtros ofrecen una
nueva secuencia de aproximación al filtro ideal, similar a los de Butterworth o
del Coseno Levantado. Aunque en el caso de los filtros DTFT, éstos vengan con
sus propios diferenciadores, como se verá en la siguiente subsección.
Diferenciadores Pasabanda
La ventaja de los filtros DTFT es que vienen acompañados con las derivadas
de los O-splines. La gráfica superior de la figura 2 muestra la primera derivada
de los splines de la figura 1. Sus respuestas en frecuencia se grafican abajo. Note
que si
es la respuesta en frecuencia del k -ésimo filtro pasabajas, entonces la
respuesta en frecuencia del correspondiente diferenciador es
y sus respuestas en frecuencia tienen una ganancia lineal en la banda de paso.
Similarmente, la segunda derivada de los O-splines se ilustra en la gráfica
superior de la figura 3. De nuevo, estas corresponden a la derivada de los
anteriores. Su respuesta en frecuencia está graficada abajo. Estos tienen una
ganancia parabólica en la banda de paso ya que
.
Finalmente, el renglón de graficas de la figura 4 ilustra los O-splines de K=0
a K=3 , y los vectores bajo cada una de ellas, ilustran sus progresivas derivadas
de arriba hacia abajo. Como puede verse, los altos grados requieren ventanas de
observación más grandes, pero ofrecen más detalles de los eventos dinámicos, y
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

49

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

mejoran la exactitud paramétrica. Note cómo las diagonales son combinaciones
lineales de traslaciones del primer spline de la correspondiente diagonal, indicando
que residen en el subespacio que aloja dicho spline. En la siguiente sección,
se comparan los sincrofasores y los parámetros estimados con el conjunto de
diferenciadores de primer y tercer grado (K=1 y K=3).

Fig. 2. Primera derivada de las O-splines (gráfica superior) y respuesta en frecuencia
(gráfica inferior) del primer diferenciador pasabajas, K=0,1, … ,5 , y 11.

Fig. 3. Segunda derivada de los O-splines y respuestas en frecuencia del segundo
diferenciador pasabajas, K=0,1, … ,5 , y 11 .

50

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Fig. 4. O-splines (primer renglón) y derivadas de los bancos de filtro DTFT pasabajas
(columnas), K=0, 1, 2, 3 .

RESULTADOS: ESTIMACIÓN DE SINCROFASORES
La estimación de sincrofasores es una aplicación interesante de la DTFT. Con
la DTFT es posible estimar no sólo las excursiones de amplitud y fase de voltajes
y corrientes durante una oscilación de potencia, sino también sus fluctuaciones
de frecuencia, y su tasa de cambio (ROCOF). En esta sección se ilustran los
estimados de voltajes trifásicos de una interesante oscilación real de un sistema
de potencia de 50 Hz, cuyas señales fueron grabadas a 20 muestras por período
fundamental (1 kHz).
La figura 5 muestra en línea punteada la señal del Voltaje C durante una
rápida oscilación, junto con la envolventes de amplitud obtenidas con K=1 y
K=3 , respectivamente. Las estimaciones son calculadas deslizando la ventana de
observación punto por punto, produciendo estimados puntuales. Por otra parte, la
figura 6 muestra las estimaciones de fase de los tres voltajes. Como puede verse,
el caso de oscilación corresponde a un vaivén muy rápido.
La derivada del ángulo de fase ofrece la fluctuación de frecuencia durante
la oscilación. La gráfica de arriba en la figura 7 muestra las estimaciones de
frecuencia del Voltaje C. Los cruces por la línea f=50 Hz marcan los puntos de
máximos y mínimos de la gráfica de fase en la figura 6. Es evidente que el análisis
DTFT puede rastrear muy rápidas excursiones de frecuencia (mucho más grandes
que las cotas del estándar). Por otra parte, la gráfica de abajo de la figura 7 ilustra
la derivada de frecuencia (ROCOF) del evento en Hz/s. Nuevamente, sus cruces
por cero marcan los máximos y mínimos de la curva en la gráfica superior.
Finalmente, la figura 8 muestra el TPE definido en (11), calculado sobre
intervalos de un ciclo, entre la señal dada y la estimada, sintetizada con estimados
instantáneos (punto a punto). Como se esperaba, los errores obtenidos con K=1
son mayores que los de K=3 , sin embargo ambas aproximaciones son muy pobres.
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

51

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Fig. 5. Voltaje C durante un vaivén de potencia (línea punteada), y envolventes de
amplitudes estimadas punto por punto con K=1 (línea a rayas) y K=3 (línea continua).

Fig. 6. Ángulo de fase de voltajes A, B, y C, durante la oscilación de potencia calculados
con K=1 (línea a rayas) y K=3 (línea continua).

52

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Fig. 7. Excursión de frecuencia del Voltaje C (arriba), con K=1 en línea a rayas y K=3 en
línea continua. Al fondo su derivada (ROCOF) estimada con K=3 .

Figure 8: TPEs calculado punto a punto en intervalos de un ciclo, con K=1 y K=3 .

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

53

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Fig. 9. Estimados de amplitud y fase del Voltaje C con O-splines de 3 er orden contraídos
a dos ciclos.

Aparentemente hemos encontrado una señal anómala para la DTFT. Note los
errores pico de la figura 8 se deben a las caídas de frecuencia de la figura 7, y
que las mejores aproximaciones se encuentran bajo los topes de las fluctuaciones
cóncavas. Además, las formas parabólicas de frecuencia se van haciendo cada
vez más angostas cuando el tiempo avanza, desde 10 hasta 3 ciclos. Como los
O-splines son de 4 períodos, la suposición de fluctuaciones suaves es únicamente
válida cuando las fluctuaciones parabólicas son más anchas de 4 ciclos. Esto
explica el incremento del error en la figura 8, hasta los más grandes obtenidos
después del 150 avo ciclo.

Fig. 10. TPE en Voltaje C obtenido con O-splines de 3 er orden contraídos a 2-cycles

54

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Afortunadamente, la DTFT ofrece una amplia gama de soluciones. El
inconveniente anterior se resuelve submuestreando las curvas flexibles O de orden
3 por un factor de 2 , y escalándolas para obtener ganancia unitaria en el filtro
pasabajas. De esta manera, los O-splines son mucho más angostas (de 2 ciclos). La
figura 9 muestra las amplitudes y fases estimadas del voltaje C con estos splines
contraídos. Este cambio reduce el TPE como se ilustra en la figura 10. Note que
las fluctuaciones parabólicas continúan manifestándose en esta gráfica.
RESULTADOS: SEPARACIÓN DE MODOS DE OSCILACIÓN
En esta sección se usa la DTFT de 3er orden para separar los modos
electromecánicos 16 de la oscilación de potencia del anterior vaivén. Como las
frecuencias de los modos tienen que conocerse a priori, esta aplicación es aún un
análisis post mortem. Esta aplicación muestra que la DTFT is capaz de detectar
modos con frecuencia modulada.
La oscilación de potencia instantánea aparece en la gráfica superior de la
figura 11, y su espectro normalizado se ilustra en la de en medio. Contiene
un modo en f0 =0 Hz, y otro en f1 =15.7 Hz. La oscilación tiene también tres
pequeños modos perceptibles de alta frecuencia. Una a f2 =100.48 Hz, la otra a
f3 =113.04 Hz, y la tercera a f4 =128.74 Hz. Como puede verse, las frecuencias
de estos modos no son múltiples de la primera (en 15.7 Hz). La gráfica inferior
ilustra la respuesta en magnitud de los filtros DTFT empleados en el análisis.
Estos fueron diseñados como sigue: Un ciclo fundamental de la oscilación de
potencia (64 ms) contiene 64 muestras. Por tanto, la DTFT debe incluir 32
armónicas. La ventana de observación de los filtros es por tanto de 256 ms. Los
tres filtros pasabanda de alta frecuencia se sintonizan en las frecuencias centrales
de cada modo.

Fig. 11. Oscilación de potencia instantánea (arriba), su espectro normalizado (en medio),
y la respuesta en magnitud de los filtros DTFT (al fondo).

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

55

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

La figura 12 ilustra los modos estimados, y al fondo la oscilación de potencia
reconstruida comparada con la original. La secuencia de cada modo m es
calculada de los coeficientes instantáneos Taylor Fourier
simplemente como
, ya que la contribución de las derivadas
en el
centro del intervalo es cero. Como puede verse, el modo cero dura los primeros
2 segundos, y el primer modo durante los últimos 4 segundos, mientras que el
resto de los modos vive únicamente medio segundo justo después de la mitad del
intervalo de observación. Estas gráficas muestran que la DTFT es capaz de separar
eventos en tiempo y frecuencia. Divide el evento en tres intervalos: uno antes
de la falla, el otro durante la falla, y el último después de la falla. En la gráfica
inferior, es patente que la oscilación de potencia reconstruida (línea punteada)
se ajusta bien a la oscilación original. La energía del error es 5 % de la energía
de la señal de oscilación. Hay un pequeño error debido a que la separación de
los dos primeros modos no es perfecta, es decir que ellos comparten energía en
las bandas de transición de los filtros correspondientes (ver gráfica inferior de
la figura 11).

Fig. 12. Modos de oscilación y al fondo la oscilación de potencia sintética, comparada
con la señal original de oscilación.

Las técnicas de descomposición de modos tradicionales generalmente
consideran la componente cero como una constante que se elimina mediante la
sustracción del promedio de la señal antes del análisis. Esta consideración es
una herencia de la manera fourierana de pensar. La descomposición de modos
con la DTFT muestra claramente que, en general, el modo cero fluctúa, y debe
considerarse como un modo de oscilación per se, ya que contiene información
dinámica importante, como se muestra en lo que sigue.
La amplitud del modo cero y su primera derivada se muestra en las gráficas
de la figura 13. Note que los cruces por cero de la primera derivada corresponden
a los máximos y mínimos de la amplitud. Lo mismo es válido para la segunda
derivada mutatis mutandis. Las derivadas de la DTFT son muy exactas.

56

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Fig. 13. Amplitud del modo cero, y sus primeras dos derivadas.

Por otra parte, la figura 14 muestra en la gráfica superior la envolvente de
amplitud del primer modo en MW, y al fondo su primera derivada en MW/s. Hay
una patente infiltración del modo cero, que es amplificada por el diferenciador.
Cuando este modo desaparece en el intervalo postfalla, se suavizan tanto la
amplitud como su derivada. Note que dos picos delimitan la duración de la
falla.

Fig. 14. Envolvente de amplitud del primer modo en MW (gráfica superior), y su primera
derivada en MW/s (gráfica inferior).
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

57

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Por último, la gráfica superior de la figura 15 muestra la fase y la del fondo su
derivada. De nuevo, la infiltración del modo cero es patente en la gráfica de abajo.
Sin embargo, es evidente que el primer modo es de frecuencia modulada, ya que
su frecuencia inicia en 0 Hz, y crece exponencialmente con pequeñas fluctuaciones
hasta alcanzar 15.6 Hz en t=3 s, donde se mantiene hasta el final del registro. Esta
evolución de la frecuencia se muestra con menos resolución en el espectrograma
ilustrado en la Fig. 4, calculado con una secuencia de transformadas rápidas de
Fourier (FFTs) usando una ventana rectangular de 4 ciclos (256 muestras). La
variación de frecuencia es también patente en la oscilación de potencia misma
en la gráfica superior de la figura 16, en la cual los intervalos pico a pico de la
oscilación disminuyen paulatinamente en la medida que la frecuencia aumenta.
Por lo tanto, la DTFT descubre una frecuencia dinámica no percibida por los
métodos tradicionales de descomposición de modos, los cuáles asumen modos
de frecuencia constante.

Fig. 15. Fase del primer modo (gráfica superior) y su frecuencia (gráfica inferior).

Los mismos estimados pueden obtenerse para los últimos tres modos en la falla.
Pero los analizados son suficientes para mostrar que la DTFT ofrece separación
tiempo frecuencia, y puede tratar con modos de frecuencia modulada. En 16 el
rendimiento del análisis con la 3 er DTFT se comparó con los métodos de Prony,
11
el algoritmo de realización eigensistema (ERA), 25 y el Matrix Pencil . 26. De los
modos interárea analizados en 16 (en 0.133 , 0.399 , 0.532 , 0.665 , y 0.798 Hz),
se concluyó que la DTFT puede aplicarse a oscilaciones de baja frecuencia. Sin
embargo, note que el análisis de modos de más baja frecuencia requieren ventanas
más largas; por ejemplo, un modo de 0.1 Hz necesita una ventana de 40 s. Sin
embargo, dichos modos pueden también extraerse con el filtro pasabajas.

58

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

Fig. 16.: Espectrograma de la oscilación de potencia.

DISCUSIÓN
Con respecto a la aplicación de sincrofasores, los O-splines ofrecen un serie
de elegantes soluciones para las clases P y M del Estándar. 4. Los resultados
muestran que los estimados de la DTFT ofrecen información dinámica mucho más
rica que la especificada por dicho Estándar. Además, el error fasorial total evalúa
la calidad del conjunto de parámetros estimados. Con relación al problema de
detección de modos de oscilación, la DTFT ofrece separación tiempo frecuencia
de modos modulados en frecuencia o modos de frecuencia constante. Finalmente,
la elegante teoría matemática detrás de la DTFT ofrece una solución unificante
de dos problemas importantes en medición de sistemas de potencia de área
amplia, tradicionalmente considerados como completamente independientes. Sin
embargo, cabe señalar que la DTFT asume que la energía espectral de la señal
se concentra alrededor de ciertas frecuencias, y que en la ventana temporal de
observación la envolvente compleja sea tan suave como para ser aproximada
por un polinomio de Taylor. En consecuencia, la DTFT es incapaz de extraer
transitorios muy rápidos con un espectro demasiado amplio, ya que la separaría
en varias componentes.
CONCLUSIÓN
Los O-splines permiten sintonizar filtros DTFT en un cierto número de
frecuencias, reduciendo la complejidad numérica de la DTFT. Los coeficientes
Taylor Fourier son muy útiles para el análisis multiresolución de señales
oscilatorias de frecuencia fluctuante. El caso ilustrado de señal demuestra que
existen señales de sistemas de potencia reales con fluctuaciones mucho más
complejas que las señales de prueba del estándar de sincrofasores del IEEE. En lo
concerniente al problema de separación de modos, la DTFT es capaz de separarlos
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

59

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

en tiempo y en frecuencia, incluyendo el modo oscilatorio cero, tradicionalmente
considerado como constante.
La DTFT ofrece una única teoría para resolver dos problemas importantes de
sistemas de potencia considerados tradicionalmente como independientes, y abre
el camino a interpretaciones más precisas y exactas de los eventos oscilatorios,
dando lugar a nuevo conocimiento. La siguiente etapa es usar los O-splines con
frecuencia adaptiva, y obtener soluciones en tiempo real para la separación de
modos de oscilación.
AGRADECIMIENTO
El autor agradece amablemente a Jörg Blumschein por haber aportado el
registro de las señales de oscilación analizadas en éste artículo.
REFERENCIAS
1. J. G. Proakis and D. K. Manolakis, Digital Signal Processing, 4th ed. Upper
Saddle River, N.J: Pearson, 2006.
2. M. A. Platas-Garza and J. A. De la O Serna, “Dynamic harmonic analysis
through Taylor-Fourier transform,” IEEE Trans. Instrum. Meas., vol. 60,
no. 3, pp. 804–813, 2011. [Online]. Available: http://dx.doi.org/10.1109/
TIM.2010.2064690
3. J. A. de la O Serna, “Analyzing power oscillating signals with the o-splines
of the discrete taylor–fourier transform,” IEEE Trans. Power Syst., vol. 33,
no. 6, pp. 7087–7095, Nov 2018.
4. “IEEE standard for synchrophasor measurements for power systems,” IEEE
Std C37.118.1-2011 (Revision of IEEE Std C37.118-2005), pp. 1–61, Dec
2011.
5. A. G. Phadke and B. Kasztenny, “Synchronized phasor and frequency
measurement under transient conditions,” IEEE Trans. Power Del., vol. 24,
no. 1, pp. 89–95, Jan 2009.
6. R. Ghiga, K. Martin, Q. Wu, and A. Nielsen, “Phasor measurement unit test
under interference conditions,” IEEE Trans. Power Del., vol. PP, no. 99, pp.
1–1, 2017, DOI:10.1109/TPWRD.2017.2691356.
7. D. Macii, D. Petri, and A. Zorat, “Accuracy analysis and enhancement of
DFT-based synchrophasor estimators in off-nominal conditions,” IEEE Trans.
Instrum. Meas., vol. 61, no. 10, pp. 2653–2664, Oct 2012.
8. M. Karimi-Ghartemani, B. T. Ooi, and A. Bakhshai, “Application of enhanced
phase-locked loop system to the computation of synchrophasors,” IEEE Trans.
Power Del., vol. 26, no. 1, pp. 22–32, Jan 2011.
9. I. Kamwa, A. K. Pradhan, and G. Joos, “Adaptive phasor and frequencytracking schemes for wide-area protection and control,” IEEE Trans. Power
Del., vol. 26, no. 2, pp. 744–753, April 2011.
10. J. S. Gasca and D. Trudnowski, “Identification of electromechanical
modes in power systems,” IEEE Power and Energy Society, Task Force on
Identificatioin of electromechanical modes, Tech. Rep., June 2012.

60

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�O-splines para analizar señales de oscilaciones de potencia / José Antonio de la O Serna.

11. J. F. Hauer, C. J. Demeure, and L. L. Scharf, “Initial results in Prony analysis
of power system response signals,” IEEE Trans. Power Syst., vol. 5, no. 1,
pp. 80–89, Feb 1990.
12. J. Rommes, N. Martins, and F. Freitas, “Computing rightmost eigenvalues
for small-signal stability assessment of large scale power systems,” in IEEE
PES General Meeting, July 2010, pp. 1–1.
13. J. W. Pierre, D. J. Trudnowski, and M. K. Donnelly, “Initial results in
electromechanical mode identification from ambient data,” IEEE Trans. Power
Syst., vol. 12, no. 3, pp. 1245–1251, Aug 1997.
14. A. R. Messina and V. Vittal, “Nonlinear, non-stationary analysis of interarea
oscillations via Hilbert spectral analysis,” IEEE Trans. Power Syst., vol. 21,
no. 3, pp. 1234–1241, Aug 2006.
15. A. Q. Zhang, L. L. Zhang, M. S. Li, and Q. H. Wu, “Identification of dominant
low frequency oscillation modes based on blind source separation,” IEEE
Trans. Power Syst., vol. PP, no. 99, pp. 1–1, 2017.
16. J. A. De la O Serna, J. M. Ramirez, A. Zamora Mendez, and M. R. A. Paternina,
“Identification of electromechanical modes based on the digital Taylor-Fourier
Transform,” IEEE Trans. Power Syst., vol. 31, no. 1, pp. 206–215, 2016.
[Online]. Available: http://dx.doi.org/10.1109/TPWRS.2015.2403290
17. J. A. De la O Serna, “Synchrophasor measurement with polynomial phaselocked-loop Taylor-Fourier filters,” IEEE Trans. Instrum. Meas., vol. 64,
no. 2, pp. 328–337, 2015. [Online]. Available: http://dx.doi.org/10.1109/
TIM.2014.2344333
18. I. Daubechies, Ten Lectures on Wavelets. Society for Industrial and Applied
Mathematics, 1992. [Online]. Available: http://epubs.siam.org/doi/abs/10.1
137/1.9781611970104
19. J. A. De la O Serna, “Dynamic phasor estimates for power system oscillations,”
IEEE Trans. Instrum. Meas., vol. 56, no. 5, pp. 1648–1657, 2007. [Online].
Available: http://dx.doi.org/10.1109/TIM.2007.904546
20. M. A. Platas-Garza and J. A. De la O Serna, “Dynamic phasor and frequency
estimates through maximally flat differentiators,” IEEE Trans. Instrum.
Meas., vol. 59, no. 7, pp. 1803–1811, 2010. [Online]. Available: http://dx.doi.
org/10.1109/TIM.2009.2030921
21. M. Vetterli, K. Kovacevic, and V. K. Goyal, Foundations of Signal Processing,
3rd ed. Cambridge, UK: Cambridge University Press,2014, available at http://
www.fourierandwavelets.org/.

Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

61

�Colaboradores

Bretón Jiménez, Emmanuel
Se encuentra en el proceso de titulación con la
modalidad articulo científico para obtener su
grado de Licenciatura en Ingeniería Química en la
División Académica de Ingeniería y Arquitectura
de la Universidad Juárez Autónoma de Tabasco. Su
trabajo de investigación lo realizó durante el Verano
Científico Programa Delfín en la UANL.
Bayer, Carolyn L. Bayer
Es profesora asistente de Ingeniería Biomédica en la
Escuela de Ciencias e Ingeniería de la Universidad
Tulane, Universidad de Lousiana. Es posdoctorada
del Ruth L. Kirschstein National Research Service
Award (NRSA) en la Universidad de Texas en
Austin. Ingeniera Electricicta de Case Western
Reserve University, y doctorada en Ingeniería
Biomédica en la Universidad de Texas en Austin.
Cantú Mata, José Luis
Ingeniero Administrador de Sistemas. Maestro
en Administración Industrial y de Negocios, con
orientación en Comercio Exterior. Doctor en
Filosofía, con especialidad en Administración,
todos por la UANL. Profesor-Investigador de la
FIME-UANL.
Dávila Guzmán, Nancy Elizabeth
Profesora de tiempo completo en la Facultad de
Ciencias Químicas de la UANL y líder del cuerpo
académico UANL-CA-49 de Ingeniería Química.
De la O Serna, José Antonio
Doctor en Telecomunicaciones por la Escuela
TELECOM Paris Tech, Francia (1982). Entre
1982 y 1986 trabajó en el ITESM. De 1988 a 1993
trabajó en el Politécnico de Yaoundé, Camerún.

62

Actualmente es Profesor Investigador de la UANL.
Es miembro del SNI.
Emelianov, Stanislav Y.
Es profesor de la Escuela de Ingeniería Eléctrica
y Computación de Georgia Tech. Director del
Ultrasound Imaging and Therapeutics Research
Laboratory en el Georgia Institute of Technology.
Cuenta con la licenciatura (1986) y maestría (1989)
en física y acústica. Doctorado en física (1993) de
la Universidad Estatal de Moscú, Rusia. En 2002
formó el Ultrasound Imaging and Therapeutics
Research Laboratory en la Universidad de Texas
en Austin.
Hernández Rivera, Miguel Ángel
Obtuvo su Doctorado en la Facultad de Ciencias
Químicas de la UNAM. Actualmente se desempeña
como profesor de tiempo completo en la División
Académica de Ingeniería y Arquitectura de la
Universidad Juárez Autónoma de Tabasco, pertenece
al Cuerpo Académico de Materiales Avanzados para
Ingeniería, en la línea de investigación Obtención
de Materiales y Procesos para Control ambiental.
López Guerrero, Francisco Eugenio
Ingeniero Mecánico Electricista e Ingeniero en
Control y Computación de la UANL, Maestro en
Ciencias de la Administración con especialidad en
Sistemas por la misma Universidad, durante estos
estudios participó en la Universidad Técnica de
Hamburgo, Alemania en donde desarrolló su tesis
de maestría. Doctor en Ingeniería de Materiales en la
Universidad Autónoma de Nuevo León trabajando
en conjunto con el Departamento de Materiales
y Automatización de la Universidad Técnica de
Hamburgo, Alemania. Profesor de tiempo completo
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Colaboradores

de la Coordinación de Ingeniería Mecatrónica de la
FIME. Miembro del Cuerpo Académico “Sistemas
Integrados de Manufactura”.
Loredo Cancino, Margarita
Profesora de tiempo completo en la Facultad de
Ciencias Químicas de la UANL y miembro del
cuerpo académico UANL-CA-49 de Ingeniería
Química.
Luke P. Geoffrey
Es profesor asistente del ingeniería en Darmouth
Engennering. Cuenta con la licenciatura en
Ingeniería Computacional y Matemáticas de la
Universidad de Wyoming (2007), Maestría en
Ingeniería Eléctrica de la misma universidad
(2009), y Doctorado en Ingeniería Eléctrica de la
Universidad de Texas en Austin (2013). Estuvo en el
uth L. Kirschstein National Research Service Award
(NRSA) en el Departamento de Ingeniería Eléctrica
de la Universidad de Texas en Austin.
Melgar Urbina, Edwin Javier
Obtuvo su grado de Licenciatura en Ingeniería
Química en la División Académica de Ingeniería y
Arquitectura de la Universidad Juárez Autónoma
de Tabasco. Actualmente, estudia la M.C. con
Orientación en Microbiología Aplicada en la
Facultad de Ciencias Químicas de la UANL.

Ingenierías, Octubre-Diciembre XXIII, No. 89

Morales Avalos, Jorge Eduardo
Ingeniero en Mecatrónica por la Universidad
Autónoma de Nuevo León. En 2014, realizó
una estancia de investigación en el Centro de
Supercomputación de Barcelona, España. Maestro
en Ciencias en Mecatrónica por la Universidad
de Siegen en Alemania. Desde 2018 es estudiante
de doctorado, investigador y docente de tiempo
completo en el departamento de Manufactura
Automatizada y Ensamble de la Universidad de
Siegen. Enfocado en el desarrollo de sistemas
robóticos suaves.
Ramírez Cruz, Francisco
Ingeniero Mecánico Electricista egresado de la
Facultad de Ingeniería Mecánica y Eléctrica de la
UANL, Es Maestro en Ciencias de la Mecatrónica
de la Universidad Técnica de Hamburgo, Alemania.
Dirigió el departamento de Somatoprótesis de
la Facultad de Medicina de la UANL. Doctor en
Ingeniería de materiales en la UANL trabajando
en conjunto con el Departamento de Materiales
y Automatización de la Universidad Técnica de
Hamburgo, Alemania. Profesor de tiempo completo
del Departamento de Mecatrónica de la Facultad
de Ingeniería Mecánica y Eléctrica. Miembro
del Cuerpo Académico “Sistemas Integrados de
Manufactura”.

63

�Información para colaboradores

Se invita a profesionistas, profesores e investigadores
a colaborar en la revista Ingenierías con: artículos de
divulgación científica y tecnológica, artículos sobre los
aspectos humanísticos del quehacer ingenieril y reportes
de investigación.
El envío de artículos a la revista Ingenierías para su
publicación implica el ceder los derechos de autor a la
UANL.
Es requisito que las colaboraciones sean producto del
trabajo directo de los autores estableciendo claramente su
contribución; y que estén escritas en un lenguaje claro,
didáctico y accesible. Las contribuciones no deberán
estar redactadas en primera persona.
Todos los artículos recibidos estarán sujetos a
arbitraje de tipo doble anónimo siendo el veredicto
inapelable. Los criterios aplicables a la selección de
textos serán: originalidad, rigor cientíﬁco, exactitud de
la información, el interés general del tema expuesto y
la claridad del lenguaje. Los artículos aprobados serán
sujetos a revisión de estilo.
CRITERIOS EDITORIALES
Los autores de artículos de revisión o divulgación
deberán contar con una producción directa reconocida en
la temática de interés de la revista. Estos trabajos deben
ofrecer una panorámica del campo temático, separar
las dimensiones del tema, mantener la línea de tiempo
y presentar una conclusión que derive del material
presentado.
Las contribuciones sobre modelación y simulación
deben estar científicamente dentro del propio trabajo.
Los trabajos con base en encuestas de opinión o
entrevistas describiendo su impacto social, especialmente
en áreas relacionadas con la ingeniería, deberán incluir la
metodología y aspectos estadísticos tanto para su diseño
como para el análisis de las mediciones y resultados, así
como la validación de las correlaciones que pudieran
presentarse.

64

No se consideran para publicación protocolos de
investigación, proyectos, propuestas o trabajos de
carácter especulativo.
Los artículos a publicarse en partes, deben enviarse
al mismo tiempo, pues se arbitrarán juntas.
LINEAMIENTOS EDITORIALES
Es requisito enviar para su consideración editorial:
artículo, material gráfico, fichas biográficas de cada autor
con un máximo de 100 palabras, en formato electrónico
.doc en Word, por e-mail a la dirección:
revistaingenierias@uanl.mx
El título del artículo no debe exceder de 80 caracteres.
El número máximo de autores por artículo es cinco.
La extensión de los artículos no deberá exceder de 15
páginas tamaño carta (incluyendo gráficas y fotos) en
tipografía Times New Roman de 11 puntos a espacio
sencillo.
Los artículos deben incluir un resumen tanto en
español como en inglés, de no más de 100 palabras, así
como un máximo de 5 palabras clave tanto en español
como en inglés. Las referencias deberán ir numeradas en
el orden citado en el texto.
Las fichas bibliográficas incluirán, en orden, los
siguientes datos: Autores o editores, título del artículo,
nombre del libro o de la revista, lugar, empresa editorial,
año de publicación, volumen y número de páginas.
Debe incluirse al menos una imagen o gráfica por
página, con resolución de al menos: 300 dpi y 15 cm
en su lado más pequeño. Las imágenes además de estar
incluidas en el artículo, deben enviarse en archivos
individuales en formato .tif, .eps o .jpg
CONTACTO
Facultad de Ingeniería Mecánica y Eléctrica
Universidad Autónoma de Nuevo León,
Edificio 7, primer piso, ala norte.
Tel.: 8329-4000 Ext. 5854
E-mail: revistaingenierias@uanl.mx
Ingenierías, Octubre-Diciembre 2020, Vol. XXIII, No. 89

�Código de ética

Autores
Los autores deben presentar una narración concisa y
exacta del trabajo desarrollado, así como una discusión
objetiva de su significado intelectual y científico.
Los autores deben abstenerse de ofrecer los mismos
manuscritos que se encuentren en consideración por otras
publicaciones.
Los autores deben incluir en su manuscrito detalles
suficientes y referencias a fuentes de información
públicas para hacer posible la reproducción del trabajo
por terceros.
Los autores deben abstenerse de presentar críticas
personales en sus trabajos.
Los autores deben citar aquellas publicaciones que son
antecedentes esenciales para comprender el trabajo.
Los autores deben abstenerse de incluir información
que hayan obtenido mediante comunicación privada que
no se localice en publicaciones.
Los autores deben abstenerse de incluir información
que hayan obtenido de manera confidencial sin el permiso
explícito correspondiente.
Los autores deben abstenerse de incluir información
obtenida en el proceso de servicios confidenciales, tales
como documentación para concursos o solicitudes de
becas.
Los autores deben abstenerse de citar publicaciones
que no se relacionen o que sólo se relacionen remotamente
con la materia.

Los autores deben reconocer mediante una nota de
agradecimiento el apoyo de las instituciones y organismos
que hayan contribuido significativamente al desarrollo del
trabajo, así como a colaboradores que hayan contribuido
de manera importante, pero sin que hayan llegado a
cumplir con el criterio de coautoría, si los hubiera.
Los autores deben reconocer mediante una nota de
agradecimiento el apoyo a colaboradores fallecidos
que hayan contribuido de manera importante, pero sin
que lleguen a cumplir con el criterio de coautoría, si los
hubiera, señalando la fecha de su muerte.
Los autores deben abstenerse de utilizar nombres
ficticios o seudónimos.
Los autores deben responsabilizarse del material que
presentan en su manuscrito.

Revisores
Los revisores deben declinar cualquier invitación para
evaluar un manuscrito si no se consideran calificados,
carecen de tiempo para juzgar o se les presenta algún
conflicto de intereses, tal como encontrarse vinculados
estrechamente a los autores o al trabajo a evaluar.
Los revisores deben manifestar al editor cualquier
conflicto de intereses que detecten.
Los revisores deben considerar un manuscrito enviado
para revisión como un documento confidencial.
Los revisores deben abstenerse de expresar críticas
personales.

Los autores deben abstenerse de incluir como autores
a terceros que no cumplan con el criterio de coautoría, el
cual consiste en la contribución significativa al desarrollo
y preparación del trabajo.

Los revisores deben explicar y apoyar sus juicios de
manera suficiente para que el editor, los miembros de
cuerpo editorial y los autores comprendan el fundamento
de las observaciones.

Los autores deben incluir a los coautores fallecidos
que cumplan con el criterio de coautoría, asentando la
fecha de su muerte.

Los revisores deben abstenerse de utilizar o difundir
información, argumentos o interpretaciones no publicadas
contenidas en un manuscrito bajo consideración,

Ingenierías, Enero-Marzo 2020, Vol. XXIII, No. 86

67

�Código de ética

excepto con el consentimiento expreso de los autores
posteriormente al proceso de evaluación.
Los revisores deben considerar en su revisión posibles
errores o fallas de los autores al citar el trabajo relevante
de otros.
Los revisores deben informar al editor si encontraran
alguna semejanza substancial entre el manuscrito y
cualquier otro trabajo.
Los revisores no deberán intentar contactar a los
autores, si hubieran inferido su identidad, previamente a
haber emitido su fallo.

Editor
El editor debe dar consideración justa e imparcial
a todos los manuscritos ofrecidos para su publicación,
juzgando cada uno de sus méritos científicos o tecnológicos,
sin prejuicios de raza, género, religión, creencia, origen
étnico, ciudadanía, filosofía o política del autor.
El editor debe considerar un manuscrito enviado para
revisión como un documento confidencial.
El editor debe abstenerse de expresar crítica
personal.
El editor debe explicar y apoyar su juicio final
para que los autores comprendan el fundamento de las
observaciones.
El editor debe abstenerse de utilizar la información
no publicada, argumentos o interpretaciones desplegados
en un manuscrito sometido, excepto cuando cuente con
el permiso del autor.
El editor deben abstenerse de desplegar información
sobre un manuscrito en proceso de revisión o publicación a
ninguna persona fuera de aquellos a los que se les solicite
consejo profesional.
El editor debe respetar la independencia intelectual
de los autores.
El editor debe procesar los manuscritos con
diligencia.
El editor debe ejercer su responsabilidad y la autoridad
para aceptar o rechazar un artículo enviado para su
publicación.

68

El editor debe delegar en los miembros del consejo
editorial o comité técnico la autoridad para aceptar o
rechazar un artículo enviado para su publicación en casos
en que se presente conflicto de interés con el editor.
El editor debe delegar la responsabilidad y autoridad
editorial a alguno de los miembros de los consejos
editoriales cuando él sea autor o coautor de un manuscrito
que se somete a consideración de la revista.

Cuerpo Editorial (Consejos Editoriales y
Comité Técnico)
Los miembros del cuerpo editorial deberán estar
dispuestos a otorgar consejo al editor en las situaciones
requeridas.
Los miembros del cuerpo editorial deben declinar
cualquier invitación para brindar consejo si se les
presenta algún conflicto de intereses, tal como encontrarse
vinculados estrechamente a los autores o al trabajo a
evaluar.
Los miembros del cuerpo editorial deben manifestar al
editor cualquier conflicto de intereses que detecten.
Los miembros del cuerpo editorial deben considerar
un manuscrito enviado para revisión como un documento
confidencial.
Los miembros del cuerpo editorial deben abstenerse
de expresar críticas personales.
Los miembros del cuerpo editorial deben explicar y
apoyar sus juicios de manera suficiente para que el editor,
los miembros de cuerpo editorial y los autores comprendan
el fundamento de las observaciones.
Los miembros del cuerpo editorial deben abstenerse
de utilizar la información no publicada, argumentos o
interpretaciones desplegados en un manuscrito sometido,
excepto cuando se cuente con el permiso del autor.
Los miembros del cuerpo editorial deben abstenerse
de desplegar información sobre un manuscrito en proceso
de revisión o publicación a cualquier persona fuera de
aquellos que se les solicite consejo profesional.
Los miembros del cuerpo editorial deberán respetar
la independencia intelectual de los autores.

Ingenierías, Enero-Marzo 2020, Vol. XXIII, No. 86

��</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </file>
  </fileContainer>
  <collection collectionId="312">
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="3241">
                <text>Ingenierías</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="41">
            <name>Description</name>
            <description>An account of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="479089">
                <text>Revista de la Facultad de Ingeniería Mecánica y Eléctrica de la UANL. Publicada a principios de la década de los noventa, editada por Rafael Covarrubias Ortiz. Contiene información sobre las actividades académicas, estudiantiles y administrativas de la Facultad, así como investigación y difusión de la ingeniería.</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </collection>
  <itemType itemTypeId="1">
    <name>Text</name>
    <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
    <elementContainer>
      <element elementId="102">
        <name>Título Uniforme</name>
        <description/>
        <elementTextContainer>
          <elementText elementTextId="585827">
            <text>Ingenierías</text>
          </elementText>
        </elementTextContainer>
      </element>
      <element elementId="97">
        <name>Año de publicación</name>
        <description>El año cuando se publico</description>
        <elementTextContainer>
          <elementText elementTextId="585829">
            <text>2020</text>
          </elementText>
        </elementTextContainer>
      </element>
      <element elementId="53">
        <name>Año</name>
        <description>Año de la revista (Año 1, Año 2) No es es año de publicación.</description>
        <elementTextContainer>
          <elementText elementTextId="585830">
            <text>23</text>
          </elementText>
        </elementTextContainer>
      </element>
      <element elementId="54">
        <name>Número</name>
        <description>Número de la revista</description>
        <elementTextContainer>
          <elementText elementTextId="585831">
            <text>89</text>
          </elementText>
        </elementTextContainer>
      </element>
      <element elementId="98">
        <name>Mes de publicación</name>
        <description>Mes cuando se publicó</description>
        <elementTextContainer>
          <elementText elementTextId="585832">
            <text>Octubre-Diciembre</text>
          </elementText>
        </elementTextContainer>
      </element>
      <element elementId="101">
        <name>Día</name>
        <description>Día del mes de la publicación</description>
        <elementTextContainer>
          <elementText elementTextId="585833">
            <text>1</text>
          </elementText>
        </elementTextContainer>
      </element>
      <element elementId="100">
        <name>Periodicidad</name>
        <description>La periodicidad de la publicación (diaria, semanal, mensual, anual)</description>
        <elementTextContainer>
          <elementText elementTextId="585834">
            <text>Trimestral</text>
          </elementText>
        </elementTextContainer>
      </element>
      <element elementId="103">
        <name>Relación OPAC</name>
        <description/>
        <elementTextContainer>
          <elementText elementTextId="585851">
            <text>https://www.codice.uanl.mx/RegistroBibliografico/InformacionBibliografica?from=BusquedaAvanzada&amp;bibId=1751916&amp;biblioteca=0&amp;fb=20000&amp;fm=6&amp;isbn=</text>
          </elementText>
        </elementTextContainer>
      </element>
    </elementContainer>
  </itemType>
  <elementSetContainer>
    <elementSet elementSetId="1">
      <name>Dublin Core</name>
      <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
      <elementContainer>
        <element elementId="50">
          <name>Title</name>
          <description>A name given to the resource</description>
          <elementTextContainer>
            <elementText elementTextId="585828">
              <text>Ingenierías, 2020, Año 23, No 89, Octubre-Diciembre</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="39">
          <name>Creator</name>
          <description>An entity primarily responsible for making the resource</description>
          <elementTextContainer>
            <elementText elementTextId="585835">
              <text>González Treviño, José Antonio, Director</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="49">
          <name>Subject</name>
          <description>The topic of the resource</description>
          <elementTextContainer>
            <elementText elementTextId="585836">
              <text>Ciencia</text>
            </elementText>
            <elementText elementTextId="585837">
              <text>Tecnología</text>
            </elementText>
            <elementText elementTextId="585838">
              <text>Ingeniería</text>
            </elementText>
            <elementText elementTextId="585839">
              <text>Investigación</text>
            </elementText>
            <elementText elementTextId="585840">
              <text>Publicaciones periódicas</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="41">
          <name>Description</name>
          <description>An account of the resource</description>
          <elementTextContainer>
            <elementText elementTextId="585841">
              <text>Revista de la Facultad de Ingeniería Mecánica y Eléctrica de la UANL. Publicada a principios de la década de los noventa, editada por Rafael Covarrubias Ortiz. Contiene información sobre las actividades académicas, estudiantiles y administrativas de la Facultad, así como investigación y difusión de la ingeniería.</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="45">
          <name>Publisher</name>
          <description>An entity responsible for making the resource available</description>
          <elementTextContainer>
            <elementText elementTextId="585842">
              <text>Universidad Autónoma de Nuevo León, Facultad de Ingeniería Mecánica y Eléctrica</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="37">
          <name>Contributor</name>
          <description>An entity responsible for making contributions to the resource</description>
          <elementTextContainer>
            <elementText elementTextId="585843">
              <text>Aguilar Garib, Juan Antonio, Editor</text>
            </elementText>
            <elementText elementTextId="585844">
              <text>Ocañas Galván, Cyntia, Redacción</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="40">
          <name>Date</name>
          <description>A point or period of time associated with an event in the lifecycle of the resource</description>
          <elementTextContainer>
            <elementText elementTextId="585845">
              <text>01/10/2020</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="51">
          <name>Type</name>
          <description>The nature or genre of the resource</description>
          <elementTextContainer>
            <elementText elementTextId="585846">
              <text>Revista</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="42">
          <name>Format</name>
          <description>The file format, physical medium, or dimensions of the resource</description>
          <elementTextContainer>
            <elementText elementTextId="585847">
              <text>tex/pdf</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="43">
          <name>Identifier</name>
          <description>An unambiguous reference to the resource within a given context</description>
          <elementTextContainer>
            <elementText elementTextId="585848">
              <text>2021124</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="48">
          <name>Source</name>
          <description>A related resource from which the described resource is derived</description>
          <elementTextContainer>
            <elementText elementTextId="585849">
              <text>Fondo Universitario</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="44">
          <name>Language</name>
          <description>A language of the resource</description>
          <elementTextContainer>
            <elementText elementTextId="585850">
              <text>spa</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="46">
          <name>Relation</name>
          <description>A related resource</description>
          <elementTextContainer>
            <elementText elementTextId="585852">
              <text>http://ingenierias.uanl.mx/archivo.html</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="38">
          <name>Coverage</name>
          <description>The spatial or temporal topic of the resource, the spatial applicability of the resource, or the jurisdiction under which the resource is relevant</description>
          <elementTextContainer>
            <elementText elementTextId="585853">
              <text>San Nicolás de los Garza, N.L., (México)</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="68">
          <name>Access Rights</name>
          <description>Information about who can access the resource or an indication of its security status. Access Rights may include information regarding access or restrictions based on privacy, security, or other policies.</description>
          <elementTextContainer>
            <elementText elementTextId="585854">
              <text>Universidad Autónoma de Nuevo León</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="96">
          <name>Rights Holder</name>
          <description>A person or organization owning or managing rights over the resource.</description>
          <elementTextContainer>
            <elementText elementTextId="585855">
              <text>El diseño y los contenidos de La hemeroteca Digital UANL están protegidos por la Ley de derechos de autor, Cap. III. De dominio público. Art. 152. Las obras del dominio público pueden ser libremente utilizadas por cualquier persona, con la sola restricción de respetar los derechos morales de los respectivos autores</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </elementSet>
  </elementSetContainer>
  <tagContainer>
    <tag tagId="38292">
      <name>Carbón activado</name>
    </tag>
    <tag tagId="12559">
      <name>Equidad</name>
    </tag>
    <tag tagId="38293">
      <name>Imágenes fotoacústicas</name>
    </tag>
    <tag tagId="37599">
      <name>Oscilaciones de potencia</name>
    </tag>
  </tagContainer>
</item>
